Oil Fired Hot Water Boiler 5Ton 11Bar Diesel Boilers For Greenhouse
General introduction of oil fired hot water boiler
1. WNS series oil Gas fired steam boiler realize high efficient heat transfer, sufficient burning with brand burner, environment protection
2. Adopted international latest technology for big volume combustion room design, and use brand burner machine
3. Corrugated furnace design make large heat transfer area and protect furnace
4. Using spirally corrugated tube , 1-2 faster heat transfer efficiency and remove hidden danger of welding cracks
5. Adopted wet-back structure that can reduce faults rate and maintenance cost
6. Equipped with protection devices for overheating, overpressure, lacking water, leak detection, flameout etc
Advantages of hot water boiler running
1. WNS series oil Gas fired steam boiler realize high efficient heat transfer, sufficient burning with brand burner, environment protection
2. Adopted international latest technology for big volume combustion room design, and use brand burner machine
3. Corrugated furnace design make large heat transfer area and protect furnace
4. Adopted wet-back structure that can reduce faults rate and maintenance cost
5. Equipped with protection devices for overheating, overpressure, lacking water, leak detection, flameout
6. Climate compensation, on-demand heating technology
Considering to the outside temperature and users’ heat demand,boilers could control the water temperature in the support of heat source efficiency automatically so that we achieve the goal of on-demand heating and energy-saving heating.
Supply code of automatic oil fired hot water boiler for laundry
Product name | Quantity (set) |
1. Boiler main part | 1 |
2. Imported gas/oil burner | 1 |
3. Electric control box | 1 |
4. Valve & Gauge used on boiler main part | 1 |
5. Feeding water Pump | 2 |
6. Smoke chimney | 1 |
7. Water treatment equipment | 1 |
8. Steam distributor | 1 |
The above is standard, other accessories needed contact us for details |
Technical parameter of WNS fire tube boiler
Boiler model | Capacity | Pressure | Outlet temp. | Steam temp. | Fuel consump. | Thermal efficiency | |
Light oil | Heavy oil | ||||||
MW | MPa | ℃ | ℃ | kg/h | kg/h | % | |
WNS0.7-0.7/95/70-Y(Q) | 0.7 | 0.7 | 95 | 70 | 65.5 | 67.3 | 91 |
WNS1.4-0.7/95/70-Y(Q) | 1.4 | 0.7 | 95 | 70 | 129.6 | 132.2 | 92 |
WNS2.8-0.7/95/70-Y(Q) | 2.8 | 0.7 | 95 | 70 | 256 | 261.9 | 93 |
WNS4.2-0.7/95/70-Y(Q) | 4.2 | 0.7 | 95 | 70 | 380 | 390.6 | 93.2 |
WNS5.6-1.0/95/70-Y(Q) | 5.6 | 1 | 95 | 70 | 503 | 517 | 93.5 |
WNS7-1.0/95/70-Y(Q) | 7 | 1 | 95 | 70 | 628 | 643 | 93.5 |
WNS10.5-1.0/95/70-Y(Q) | 10.5 | 1 | 95 | 70 | 940 | 965 | 93.5 |
WNS14-1.0/95/70-Y(Q) | 14 | 1 | 95 | 70 | 1250 | 1301 | 93.5 |