Horizontal Natural Gas Steam Boiler 4Thr For Pasteurized Milk
Gas Steam Boiler is horizontal three pass fire tube wet back full automatic steam boiler. Gas Steam Boiler normally suitable for 500kg to 20ton/h capacity, use all kinds of gas and oil fuels,such as natural gas, lpg,lng,cng,city gas,biogas, diesel oil,heavy oil.
1. Model:WNS
2. Steam Capacity: 500 kg/hr, 1000kg/hr, 1 ton per hour, 2 ton, 3 ton, 4 ton, 6 ton, 8 ton, 10 ton, 15 ton, 20 ton
3. Design pressure:1.0Mpa(10bar), 1.25Mpa(13bar), 1.6Mpa(16bar),2.5Mpa(25bar)
4. Stem temperature: 194 degree 224 degree 350 degree 450 degree
5. Design fuel:natural gas, lpg,lng,cng,city gas,biogas, diesel oil,heavy oil
6. Structure: three pass fire tube wet back.
Gas Steam Boiler Quick details:
Steam Capacity | 1 to 20 ton/hr 0.7MW-14MW |
Fuel Applicable | Natural gas,LPG, LNG, CNG, Diesel, Light oil, Heavy oil, Kerosene, |
Working pressure | 0.4-2.5Mpa 4bar-25bar |
Steam temperature | 184℃, 194℃,226℃ |
Structure | Three pass, fire tube, wet back |
NOx emission: | <30mg/㎥ |
Heat efficiency | ≥95% |
Application | Industrial production, central heating |
Gas Steam Boiler Application:
Gas Steam Boiler Application field
1. Food industry: such as rice mills, noodle factory, canned factory, juice processing factory, tomato sauce factory, beer wine factory, etc.
2. Textile industry: textile factory, garment factory, sweater factory, socks industry, dyeing factory.
3. Petrochemical industry: steam can be used to heat oil, to strengthen the liquidity of oil;
4. Foam, furniture production: the steam can be used for producing foam. When making furniture, wood needs to be dried with steam;
4. Filling block production:steam used for drying the aerated brick;
5. Washing ironing industry: generally used in laundry, including dry cleaning machines, dryers, washing machines, dehydration machines, ironing machines, iron and other equipment supporting the use;
6. Packaging machinery industry: labeling machines, sets of standard machine
Gas Steam Boiler Fetures:
1. Safe and Intelligent Control
equipped with world famous brand burners(Baltur, Riello, Oilon), 80% configuration , making the combustion more sufficient with lower failure rate.
multiple protective functions for over-high temperature, over-high pressure, water shortage, leakage detection and flame-out, ensuring safe and reliable operation.
Independently developed PLC control panel, better match our boiler operation. Siemens PLC with 10 inch touch screen and frequency transformer, more safety and easy operation.
Explosion proof door design, prevent explosion, reduce the damage to the boiler, improve the safety of boiler.
2. High efficiency and low fuel consumption
Adopt threaded smoke tube, Increase the flow rate of the flue gas, enhance the heat transfer efficient.
Equipped with dual energy-saving devices, fuel combustion is sufficient, exhaust gas temperature is low, thermal efficiency is increased by 5%-10%
big size corrugated furnace, has large heating area, satisfy the free expansion of boiler, improve the boiler efficiency.
3. Eco-friendly and Low NOx emissio
Low nitrogen FGR combustion technology Nitrogen oxide emissions <30mg/m3;
Gas Steam Boiler technical parameter
Model | Rated capacity | Rated pressure | Rated steam temperature | Boiler efficiency | Oil Fuel consumption | Gas Fuel consumption |
t/h | Mpa | ℃ | % | ㎥/h | kg/h | |
WNS1-1.0-Y(Q) | 1 | 1 | 184 | 91 | 84.2 | 65.5 |
WNS2-1.25- Y(Q) | 2 | 1.25 | 194 | 92 | 165 | 129.6 |
WNS3-1.25-Y(Q) | 3 | 1.25 | 194 | 92.1 | 250 | 192 |
WNS4-1.25- Y(Q) | 4 | 1.25 | 194 | 93 | 323.6 | 256 |
WNS5-1.25- Y(Q) | 5 | 1.25 | 194 | 93 | 386 | 318 |
WNS6-1.25- Y(Q) | 6 | 1.25 | 194 | 93.2 | 450 | 380 |
WNS8-1.25- Y(Q) | 8 | 1.25 | 194 | 93.5 | 642 | 503 |
WNS10-1.25- Y(Q) | 10 | 1.25 | 194 | 93.5 | 805 | 628 |
WNS15-1.25- Y(Q) | 15 | 1.25 | 194 | 93.5 | 1182 | 940 |
WNS20-1.25- Y(Q) | 20 | 1.25 | 194 | 93.5 | 1597 | 1250 |
Gas Steam Boiler and auxiliary list
Number | Item | Brand | Number | Item | Brand |
1 | Boiler proper | Yuanda | 6 | Water Softener | USA Fleck |
2 | Burner | Baltur, Riello, Oilon | 7 | Steam Header | Yuanda |
3 | Electric Control Cabinet | Yuanda | 8 | Chimney | Yuanda |
4 | Economizer | Yuanda
| 9 | Deaerator | Yuanda |
5 | Water Pump
| Grundfoss
| 10 | Valves&Instrument | Gaoshan |
Inspection & Testing
Making following test before delivery.
1 Hydraulic test, ensure the standard working pressure and safety.
2 100% X-ray NDT (non-destructive inspection) report of steel plate, tube and welding rod, to ensure the quality of the entire boiler.
Supervision of Gas Steam Boiler Installation and Commissioning Service
Supervision of installation and commissioning the equipment within delivery scope is available byour service team. But the Buyer will be only in charge of:
1.The round air-tickets costs from Zhengzhou city to project site.
2.Board and lodging of seller’s workers for the entire period at the end-user’s site.
3.Necessary communication cost.
4.Service fee of Seller’s worker: USD 100/day/person, for the entire period at the end-user’s site. This quotation excludes all consumables during erection, commission and trail run, like instrument, common tools, installation auxiliaries and oil etc.
Gas Steam Boiler project case: