Fire Retardant Lighting / Compressor AC Contactor 110V with Common Mode Coil
Description:
Magnetic AC Contactor should have the high current value without being exposed to and damaged or boiling. This belongs to the quality of contactor. (Contact surface quality and weld technology) Especially at AC-3 and capacitor command, selectivity of contactor is very important.
Current which passes through the contacts causes warming when the contactor is closed. This warming is limited with the standards. For IEC60947-4-1 when continual thermal current (Ith) is passed though the main contacts, maximum increasing temperature should not exceed 65k.
Characteristics:
1. 3 pairs of main contacts: 85% Ag
2. Enclsoure: fire- retardant
3. Button: resin (bearing temperature more thant 250 degree)
2. Fixed by screw
3. AC/DC coil
4. Wide coil voltage
5. Be connected with the thermal overload relay directly
Features:
1. Convenient usage: it is not necessary to dismantle auxiliary contact block and the auxiliary contacts are workable for 100A-220A contactors
2. Withdrawable coil: it is easy to replace the coil and there is no need to disassemble the contactors
3. Various auxiliaries including contacts, delay unit, mechanical interlock unit
4. Easy wiring: using clamp type connecting terminal
5. Passing EMC test; resistant to surge impact and electromagnetic radiation
6. Wide range of operation voltage and multipurpose for AC and DC
Specifications:
Model |
UKC1-100 |
UKC1-125 |
UKC1-150 |
UKC1-180 |
UKC1-220 |
|
Rated operational current |
Ie max AC-3 |
105A |
125A |
150A |
180A |
220A |
Ie AC-1 |
150A |
150A |
200A |
230A |
260A |
|
Rated operational power in AC-3 |
220/240V |
30KW |
37KW |
45KW |
55KW |
75KW |
380/400V |
55KW |
60KW |
75KW |
90KW |
132KW |
|
415/440V |
55KW |
60KW |
75KW |
90KW |
132KW |
|
500V |
55KW |
60KW |
90KW |
110KW |
132KW |
|
660/690V |
55KW |
60KW |
90KW |
110KW |
132KW |
|
Thermal overload relays |
class 10A |
34...125A |
34...125A |
34...150A |
65…240A |
65…240A |
class 20A |
34...125A |
34...125A |
34...150A |
65…240A |
65…240A |
Coil voltage(AC) :
50Hz: 24V, 42V, 48V, 100V, 110V, 220V/230V, 240V, 380V, 400V, 415V, 440V, 500V, 550V
60Hz: 24V, 48V, 110V, 120V, 208V, 220V, 240V, 277V, 380V, 440V, 480V, 600V
Coil voltage(DC):
12V, 20V, 24V, 48V, 60V, 80V, 100V, 110V, 125V, 200V, 220V, 250V
Main application fields for AC contactors
Lighting for out-door
Car washing facilities
Crain hoist
Lighting of sports facilities
Pump
Compressor
Vending machine
Painting machine
Show case
It is possible to expand the control wire length since voltage drop in wires is small.
FAQ
A. How's the delivery time?
Depend on your quantity, usually within 20days after receiving deposit
B. Would you accept OEM/ODM service?
Glad to say that there is planning department, technical department and mould tooling center in our factory. For the OEM & ODM, it is ok for us if your brand, market shares are great.
C. Would you offer free sample?
Samples are freely provided and shipping costs is paid on your end usually.
D What's your guaranty time?
At least 2 years and depend the product
E What's your payment term?
T/T, L/C; other terms is negotiable after further check