Water Cooling Huge Loading Vibration Testing System With Onsite Installation and Professional Service
Mentek provides Water cooling and air cooling vibration test system to suit different customer applications and requirements. Whether for national customer or overseas clients, we have professionla engineers to provide onsite installation and after sales services.
Features:
* Flexible suspension system and straight line guide, strong bearing capacity, good guidance performance and high stability.
* The static stiffness of the central load airbag is large, the dynamic stiffness is small, the bearing capacity is strong, and the dynamic performance is excellent.
* Rapid self-examination diagnosis and chain protection, high safety and reliability;
* The air bag isolating and damping device makes the vibrator do not need the special foundation, perfectly reproduces the vibration wave and reduces the vibration transmission.
* Provide different use of horizontal and vertical expansion platforms;
* It can be used with all kinds of vibration controllers, and the operation is simple.
Techinical Specifications
Model | MV-300 | MV-600 | MV-1000 | MV-2000 | MV-3000 | MV-5000 | |
System main parameter | Rated sine foree(N) | 2940 | 5880 | 9800 | 19600 | 29400 | 49000 |
Random foree(N) | 2940 | 5880 | 9800 | 19600 | 29400 | 49000 | |
Shock foree(N) | 5880 | 11760 | 19600 | 39200 | 58800 | 98000 | |
Frequency rangle(HZ) | 5-4000 | 5-3000 | 5-3000 | 5-3000 | 5-2500 | 5-2500 | |
Rated acceleration (m/s2) | 980 | 980 | 1176 | 980 | 980 | 980 | |
Rated speed(m/s) | 1.1 | 0.8 | 1.8 | 1.85 | 1.5 | 1.5 | |
Rated displacement(mmp-p) | 25 | 25 | 25 | 51 | 51 | 51 | |
Max.load(kg) | 120 | 200 | 120 | 300 | 500 | 1000 | |
Power consumption(KVA) | 6.5 | 15 | 20 | 28 | 42 | 76 | |
Voltage(V) | 3 phases AC 380V ±10% AC 50 Hz | ||||||
Model | DC-300 | DC-600 | DC-1000 | DC-2000 | DC-3000 | DC-5000 | |
System main parameter | Effective mioving | 2.7 | 5.6 | 8.3 | 18 | 25 | 40 |
element mass(kg) | |||||||
Table size(mm) | 150 | 200 | 200 | 280 | 320 | 400 | |
Shaker weight (kg) | 450 | 630 | 940 | 1600 | 2000 | 3500 | |
Shaker dimension(L*W*Hmm) | 720x550x650 | 790x545x1625 | 830x680x825 | 900x570x960 | 1000x880x1060 | 1380x990x1090 | |
Model | DA-2 | KA-2 | KA-10 | KA-21 | KA-26 | KA-45 | |
Applifler parameter | Max.power output(KVA) | 2 | 3 | 10 | 21 | 26 | 45 |
Amplifier weight(KG) | 230 | 300 | 340 | 230 | 240 | 310 | |
Amplifier dimension(L*W*Hmm) | 720x545x1625 | 720x545x1625 | 720x545x1625 | 720x545x1763 | 800x545x1900 | 800x545x1900 | |
Controller | Optional | ||||||
Cooling Mode | Air cooling | ||||||
Meeting Standard | JJG190-1997/IEC68-2-6/GB/T/2423.10-1995/Q/320602SN001-2002 |
Structure:
Packaging Method