Specifications
Brand Name :
YANYE OR BAOFENG
Model Number :
YCT, YNT, FBN
Certification :
ISO9001 2008
Place of Origin :
SHANGHAI
MOQ :
I UNIT
Price :
Negotiation
Payment Terms :
T/T
Supply Ability :
299 UNIT / MONTH
Delivery Time :
60 DAYS
Packaging Details :
General packing for ocean shipping
Description

YanYe cooling equipment is widely used in petrochemical, pharmaceutical, steel, automotive, foundry, nuclear power plants, power plants, glass manufacturing, IT factories, food and other fields, and air withered systems, induction furnace, continuous casting equipment, mold, glass melting furnace, air compressors, injection molding machines, welding equipment, painting equipment and other facilities, and to partners in various fields to provide professional technical support and services.

Advantages of Closed Circuit Cooling Tower (CCCT)

Personnel Health Protection

Open cooling water system is subject to water pollution and, as a result, the bacteria of miscellaneous sorts proliferate fast to become a grave threat to human health by dissipating the bacteria containing vapor. A popular disease from open water cooling system is legionnaire that endangers human life by causing pneumonia, which is especially true for people living & working in the buildings with central air conditioners. Closed circuit cooling tower has the largest proportion of cooling water circulating inside enclosed loop, thus is not subject to water pollution. The specially designed louvers not only reduce the limited spray water drift to minimum level, but also effectively stop outside sunlight and particles from entering the tower basin cultivating the growth of bacteria.

Tube Scaling Prevention

Most scaling & fouling problems are caused by impurities brought into cooling tubes by process cooling water, which will easily damage heat rejection equipment like melting furnaces, some cases of which involve personnel safety issues. For other equipments like central air conditioner, generators, compressors etc, scaling problems are one of the main reasons for lower operation efficiency and souring maintenance cost. Closed circuit cooling tower eliminates the scaling problems by running de-mineralized process water inside the closed circuit cooling coils so that scaling problem is reduced to the lowest level if not completely eradicated.

Energy Saving

Variable frequency control ( VFC) is an option for flexible adjustment of the number and speed of working cooling fans to ambient temperature changes, the data of which can be preset at a certain figure. During winter season, the spray water stops automatically when ambient temperature drops to a certain level using only a set number of operating fans to satisfy the reduced cooling requirements.

Water Saving

CCCT system adopts 100% closed circuit circulation for process fluid that saves water from loss in any form. Special baffle is used to reduce unavoidable spray water loss to the lowest point without negative impact on the cooling efficiency. The prominent water saving nature is one of the most important factors deciding the popular use of closed circuit cooling tower.

Space Saving

Closed circuit cooling tower is designed to operate within very limited space, accounting for 1/4-1/5 that of open cooling system, saving any form of ground construction. The effective drift eliminator baffle enables closed circuit cooling towers to be used indoors close to production line without wetting the groud.

Investment Saving

Closed circuit cooling tower has self-attached water basin and fully enclosed cooling coils for preservation of cooling water that saves any form of ground construction cost. Under open cooling tower system, the large water pool is a necessity to supply all process cooling water, and the related investment will be of no use if the open cooling tower is to be re-installed to a different site.

User Friendly

Yanye closed circuit cooling tower can be controlled via remote control panel with clearly defined functional push-buttons and digital display system. Automatic Light & Sound alarm system is installed to remind the operator of extreme working conditions of the cooling system for on time adjustment; VFC technology is available for automatic setting of the cooling tower operation data following ambient changes without human interference. Computer control system is also possible under highly sophisticated cooling system requirements.

Longer Life Expectancy

Instead of adopting wooden structure or PVC cooling fills, closed circuit cooling tower is composed of copper or carbon steel cooling coils, zink-aluminum galvanized steel case and stainless steel structures etc that prolongs the trouble-free service life of closed circuit cooling tower.

Easy Installation and Maintenance

The installation of closed circuit cooling tower includes merely the connection of piping and electrical system that can be done even by technical workers without training.

Due to the scaling-free nature of closed circuit cooling tower, a great deal of human efforts for monthly or quarterly maintenance can be saved, which are normally neglected due to the busy production schedule and tend to cause sudden stop with long accummulation of scalings.

Choosing closed circuit cooling tower comes to be part of our responsibility for protection of life and environment with safe & saving industrial cooling solutions

FBN-6 6 6.8 700 12000 0.75 7.4 9 40-100A 0.37 DN50 DN40 DN25 DN20 1350(1600) 980 1850 1750 350 630
FBN-10 10 11.4 700 12000 0.75 7.4 9 40-100A 0.37 DN50 DN40 DN25 DN20 1350(1600) 980 1850 1750 400 720
FBN-15 15 17.1 700*2 10000*2 0.75*2 14.5 9 50-100A 0.75 DN65 DN40 DN25 DN20 2000(2250) 1020 2080 1980 520 940
FBN-20 20 22.8 700*2 10000*2 0.75*2 14.5 9 50-100A 0.75 DN65 DN40 DN25 DN20 2000(2250) 1020 2080 1980 580 1050
FBN-30 30 34.2 800*2 20000*2 1.5*2 29 8.4 65-100A 1.1 DN80 DN40 DN25 DN20 2500(2850) 1250 2340 2440 880 1850
FBN-40 40 45.6 800*2 20000*2 1.5*2 29 8.4 65-100A 1.1 DN80 DN40 DN25 DN20 2500(2850) 1250 2340 2440 960 2050
FBN-50 50 57 900*2 24000*2 2.2*2 58 8 65-100(I)A 2.2 DN100 DN50 DN40 DN25 2500(2850) 1250 3040 2590 1060 2250
FBN-60 60 68.4 900*2 24000*2 2.2*2 58 8 65-100(I)A 2.2 DN100 DN50 DN40 DN25 2500(2850) 1250 3040 2590 1140 2400
FBN-70 70 80 900*2 28000*2 3.0*2 65 8 80-100 3 DN100 DN50 DN40 DN25 2500(2850) 1500 3300 2800 1380 2870
FBN-80 80 91.2 1000*2 32000*2 3*2 65 8 80-100 3 DN100 DN50 DN40 DN25 2500(2850) 1660 3810 3310 1440 3150
FBN-100 100 114 1000*2 40000*2 4*2 116 8.8 80-100(I)A 4 DN125 DN50 DN40 DN25 2500(2850) 1660 3810 3310 1800 3960
FBN-125 125 142.5 1200*2 50000*2 4*2 116 8.8 80-100(I)A 4 DN125 DN50 DN40 DN25 2800(3150) 1780 3860 3360 2250 4950
FBN-150 150 171 1200*2 60000*2 5.5*2 116 8.8 80-100(I)A 4 DN150 DN50 DN40 DN25 3000(3350) 1880 3910 3410 2700 5940
FBN-175 175 200 1300*2 70000*2 5.5*2 130 11 100-100 5.5 DN150 DN50 DN40 DN25 3500(3850) 2080 4270 3770 3150 6930
FBN-200 200 228 1500*2 80000*2 7.5*2 130 11 100-100 5.5 DN200 DN80 DN50 DN40 4000(4350) 2080 4270 3770 3600 7920
FBN-250 250 285 1600*2 100000*2 7.5*2 172 9.6 125-100A 7.5 DN200 DN80 DN50 DN40 4500(4850) 2160 4850 4350 4300 9250
FBN-300 300 342 1800*2 120000*2 11*2 172 9.6 125-100A 7.5 DN200 DN80 DN50 DN40 4600(5100) 2300 4950 4450 5150 9500
FBN-350 350 399 2000*2 140000*2 11*2 232.5 8.5 150-200A 11 DN250 DN80 DN50 DN40 5000(5500) 2500 4950 4450 5950 10750
FBN-400 400 456 2400*2 160000*2 11*2 232.5 8.5 150-200A 11 DN250 DN80 DN50 DN40 5300(5800) 2650 4950 4450 6850 14500

Send your message to this supplier
Send Now

Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation

Ask Latest Price
Brand Name :
YANYE OR BAOFENG
Model Number :
YCT, YNT, FBN
Certification :
ISO9001 2008
Place of Origin :
SHANGHAI
MOQ :
I UNIT
Price :
Negotiation
Contact Supplier
Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation
Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation

SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD

Active Member
8 Years
Since 2008
Business Type :
Manufacturer, Exporter, Trading Company, Seller, Other
Total Annual :
2000-4999
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement