Specifications
Brand Name :
Iflow
Model Number :
YE-F11
Certification :
ISO9001, CE
Place of Origin :
China
MOQ :
negotiable
Price :
negotiable
Payment Terms :
T/T, L/C
Supply Ability :
2200000 units per year
Delivery Time :
4-6 weeks
Packaging Details :
wooden case pluse pallet
Name :
ElectroMagnetic flow meter
Diameter :
1" - 48"
Liner :
PTFE, rubber
Electrode :
316L / Hasteloy-C / Ti / Ta / Pt100
Pressure rating :
PN16 - 40 Mpa
Protection :
IP68
Accuracy :
0.25% , 0.5%
Power supply :
85 - 265V AC / 8-36V DC
Communication :
Modbus/GPRS/RS485/Bacnet
Description

Bacnet Electromagnetic flow meter for drinking water utility | SS316 tube | PN16 I CE

Product Description

Our Magnetic Flow Meter features all welded structure, it reduces lifecycle costs and unplanned shutdowns by accurately measuring water and wastewater flows in a variety of utility applications. It has intelligent diagnostics that help users take advantage of improved installation, maintenance and process-management practices. With fully welded sensor construction and an isolated, replaceable terminal block, these makes it the most dependable flow meter available for utility and water applications.

Work principle

The Magnetic flowmeters are often used where the liquid is fed using gravity. Be sure that the orientation of the flowmeter is such that the flowmeter is completely filled with liquid. Failure to ensure that the flowmeter is completely filled with liquid can significantly affect the flow measurement. Be especially careful when operating magnetic flowmeters in vacuum service because some magnetic flowmeter liners can collapse and be sucked into the pipeline in vacuum service, catastrophically damaging the flowmeter. Note that vacuum conditions can occur in pipes that seemingly are not exposed to vacuum service such as pipes in which a gas can condense (often under abnormal conditions). Similarly, excessive temperature in magnetic flowmeters (even briefly under abnormal conditions) can result in permanent flowmeter damage.

Industries Where Used

In order of usage, water/wastewater industry, chemical, food and beverage, oil and gas (although not for oil and gas fluids but in support of the processes), power, pulp and paper, metals and mining, and pharmaceutical.

Accuracy

Pipe Dia (mm) Velocity (m/s) Accuracy
3-20 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout
25-600 0.1-0.3 + 0.25% FS
0.3-1 + 0.5% Readout
1-15 + 0.3% Readout
700-3000 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout

Grounding

From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.

Technical data

Product name Electromagnetic flowmeter
Product type Local|compact display Remote display Signal converter
Model IYF-E IYF-F IRT
Pipe Diameter (mm) DN10-DN2000
Power supply 100-240 VAC / 18-36 VDC
Accuracy + 0.5% + 0.5% + 0.5%
Power consumption <6w <6w <6w
Enclosure rating IP65 IP68 IP65
Liquid temperature -25-120℃ -25-120℃ -25-120℃
Ambient temperature -25-50℃ -25-50℃ -25-50℃
Relative humidity 10-90% 10-90% 10-90%
Meter ratio 1:100 1:100 1:100
Flow direction Bi-direction flow Bi-direction flow Bi-direction flow
Communication RS485 / Bacnet RS485 / Bacnet RS485 / Bacnet
Signal Output 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency

Mounting notice

Bacnet Electromagnetic Field Meter Ip68 Protection For Drinking Water Utility

Bacnet Electromagnetic Field Meter Ip68 Protection For Drinking Water Utility

Model selection

Applicable metering liquid:

  • Conductive liquid media, conductivity > 5 µS/ cm
  • Various Conductive aqueous solutions, water solutions, acid & caustics
  • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
    water, effluent, fibrous, viscous, paper mill, food & beverage

Non-applicable metering medial

  • Industrial gas, compressed air, steam, or liquid with large content of gas
  • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure
    water, clean gas, etc.

Notice on the selection of local type and remote type:

Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:

  • Ambient temperature or converter display sunshine temperature is over 60 ℃
  • High humidity or corrosive air existed
  • Serious pipe vibration
  • Magnetic meter need be suspended or submersible, uneasily read out
  • Other abrasive condition
I Model
YF Electromagnetic flowmeter
TF Turbine
VF Votex
LX Vane wheel
T Ultrasonic
E/F display mode E: compact/local display, F: remote display
Pipe Dia Type (mm)
xxxx

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

500, 600, 800, 1000

Code Accuracy
1 + 0.5% FS
2 + 1.0% FS
3 + 0.2% FS
Code Type
N Converter: 12 / 24 VDC, pulse output
A Transmitter: 24VDC, 4-20mA outpt
B Intelligent, Lion battery, no local display
G Smart, local display, 4-20mA output
C1 Smart, local display, RS485
C2 Smart, local display, HART
Code Type
S Carbon steel housing
L Stainless steel housing
G High pressure housing
HL 316L electrode
HTi Titanium electrode
HTa Tantlum electrode
HC Hastelloy-C electrode
L1 Liquid media
L2 Gas media
P Pressure compensation
T Temperature compensation
PT Pressure&Temp. Compensation
F PTFE liner
X Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner

Pipe Diameter, flow volume and product dimension

Dia Flow volume (m3/h) Product dimension (mm)
(mm) Normal Min Max L D H H1
15 1.5 0.06 9.5 150 95 272 254
20 2.5 0.11 16.9 105 277 254
25 3.5 0.18 26.5 115 283 254
32 6 0.29 43.6 140 297 270
40 10 0.45 67.8 150 307 280
50 15 0.71 106.0 200 165 318 294
65 25 1.19 179.1 185 337 313
80 40 1.81 271.4 200 352 326
100 60 2.83 424.1 250 220 371 344
125 100 4.42 665 250 401 372
150 135 6.36 954 300 285 431 403
200 250 11.3 1696 350 340 486 460
250 375 17.66 2650 400 395 547 511
300 540 25.43 3817 450 445 597 565
350 735 34.62 5195 505 657 620
400 960 45.22 6785 500 565 717 675
450 1200 57.23 8588 550 615 757 727
500 1500 70 10602 600 670 817 782
600 2160 100 15268 780 917 782
700 2950 138 20781 700 895 1027 1068
800 3850 180 27100 800 1015 1137 1157

Industrial applications

Chemical Food & beverage Paper mill
Metallurgy Environment protection Hydraulic
Mining Stainless Petroleum
Pharmacy Air conditioner Effluent treatment plant
Seawater desalination Pharmacy Water treatment

Competitive advantage

  • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Process control

Bacnet Electromagnetic Field Meter Ip68 Protection For Drinking Water Utility

Calibration equipment

Bacnet Electromagnetic Field Meter Ip68 Protection For Drinking Water Utility

Send your message to this supplier
Send Now

Bacnet Electromagnetic Field Meter Ip68 Protection For Drinking Water Utility

Ask Latest Price
Brand Name :
Iflow
Model Number :
YE-F11
Certification :
ISO9001, CE
Place of Origin :
China
MOQ :
negotiable
Price :
negotiable
Contact Supplier
Bacnet Electromagnetic Field Meter Ip68 Protection For Drinking Water Utility
Bacnet Electromagnetic Field Meter Ip68 Protection For Drinking Water Utility

Shanghai I Fluid Technology Co., Ltd.

Active Member
8 Years
shanghai, shanghai
Since 1966
Business Type :
Manufacturer, Exporter
Total Annual :
15000000-20000000
Employee Number :
400~500
Certification Level :
Active Member
Contact Supplier
Submit Requirement