Items | UNIT | TECHNICAL DATA |
Rated capacities(Emax) | t | 25, 30, 40, 50, 60, 90 |
Sensitivity | mV/V | 2.0±0.005 |
Total error | F.S | ±0.03%(alloy steel), ±0.05%(50, 90t stainless steel) |
Creep error(30min) | F.S | ±0.03%, ±0.05% |
Zero balance | F.S | ±1% |
TCO | F.S/℃ | ±0.02% / 10 |
TC SPAN | F.S/℃ | ±0.02% / 10 |
Input impedance | Ω | 400±20 |
Output impedance | Ω | 352±3, 352±5(L≥15m) |
Insulation impedance | MΩ | ≥5000 |
Temperature range, compensated | ℃ | -10 ~ +40 |
Temperature range, operating | ℃ | -30~ +70 |
Maximum safe overload | F.S | 150% |
Ultimate overload | F.S | 250% |
Excitation, recommend | V | 10-12V DC |
Excitation, maximum | V | 15V DC |
Protection class | IP68(10~40t) | |
Construction | Alloy Steel, Stainless steel | |
Cable | m | Length: 10(25, 30t), 16(40, 50t), 18(60, 90t) |
mm | Diameter: φ8 | |
Wiring | Exc+(Red) Exc-(Black) Sig+(Green) Sig-(White) |