Item | Unit | Parameter | |
Accuracy Class to OIML R60 | C2 | C3 | |
Maximum Capacity (Emax) | Kg | 10, 20,50, 75, 100, 200, 250, 300, 500 | |
Minimum LC Verification Interval (Vmin) | % of Emax | 0.0200 | 0.0100 |
Sensitivity (Cn)/Zero Balance/ | mV/V | 2±0.002/0±0.02 | |
Temperature Effect on Zero Balance (TKo) | % of Cn/10K | ±0.02 | ±0.0170 |
Temperature Effect on Sensitivity(TKo) | % of Cn/10K | ±0.02 | ±0.0170 |
Hysteresis Error (dhy) | % of Cn | ±0.0270 | ±0.0180 |
Non-linearity(din) | % of Cn | ±0.0250 | ±0.0167 |
Creep(dcr) over 30 min | % of Cn | ±0.0233 | ±0.0167 |
Input(RLC)&Output Resistance(R0)& | Ω | 400±10 & 352±3 | |
Nominal Range of Excitation Voltage (Bu) | V | 5-15 | |
Insulation Resistance(Ris) at 50 Vdc | MΩ | ≥5000 | |
Service Temperature Range(Btu) | ºC | -30...+70 | |
Safe Load Limit (EL) &Breaking Load(Ed)& | % of Emax | 120&200 | |
Protection Class According to EN 60 529(IEC 529) | IP68 | ||
Material: measuring element : Cable fitting Cable sheath | Stainless or Alloy Stell Stainless steel or nickel-plated brass PVC |
Maximum Capacity(Emax) | kg | 10 | 20 | 50 | 75 | 100 | 200 | 250 | 300 | 500 |
Deflection at Emax(snom), approx | mm | 0.29 | 0.39 | |||||||
Weight(G), approx. | kg | 0.5 | ||||||||
Cable :Diameter :φ5mm Length | m | 3 |