Force measurement in small space installation, such as feeling tester for keyboard switch,
compression force measurement for hot and cold lamination machine,
and grasping force measurement for robotic hands
MODLE | Capacity | A | B | C | D | E | F | G | H |
MI-012-H7 | 5-10KG | 1 | 7 | 6.5 | 7.5 | 12 | 5 | 2 | 3.2 |
20-100KG | 2.5 | 7 | 6.5 | 7.5 | 12 | 5 | 2 | 3.2 | |
MI-012-H4 | 5-10KG | 1 | 4 | 3.2 | 0 | 12 | 0 | 2 | 1.4 |
20-50KG | 2.5 | 4 | 3.2 | 0 | 12 | 0 | 2 | 1.4 |
Capacity | 5~100kg | Material | Stainless Steel |
Rated Output | 1.0-1.5mV/V | Output Impedance | 350±3Ω |
Zero Balance | ±2%F.S. | Insulation | ≥5000MΩ/100VDC |
Non-linearity | 0.5%F.S. | Recommended Excitation | 2.5-5V |
Hysteresis | 0.5%F.S. | Maximum Excitation | 5V |
Repeatability | 0.5%F.S. | Compensated Temp Range | -10~60oC |
Creep (30min) | 0.1%F.S. | Operating Temp Range | -20~80oC |
Temp Effect on Output | 0.1%F.S./10℃ | Safe Load Limit | 120% |
Temp Effect on Zero | 0.1%F.S./10℃ | Ultimate Load Limit | 150% |
Input Impedance | 350±5Ω | Cable Size | φ2x3m |
Wire Connection | Ex + : Red; Ex - : Black; Sig +: Green; Sig - : White |