Analog Conductivity Sensor Indumax CLS54 E&H Instrument CLS54-AAA5022
Process pressure | 12 bar(174 psi)/20°C(68°F) |
Ingress protection | IP68/NEMA6P |
Measuring principle | Inductive conductivity measurement |
100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm
Process temperature: -10°C - +125°C
(14°F - 257°F)
Sterilisation: 150°C/5 bar (max. 60 min.)
(302°F / 72.5 psi)
12 bar(174 psi)/20°C(68°F)
8 bar(116 psi)/125°C(257°F)
The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products.
Indumax CLS54 measures toroidal conductivity in hygienic food & beverage and life science applications, such as:
Phase separation of product/water and product/product mixtures in pipe systems
Control of CIP (cleaning in place) processes in the return channel
Concentration control in remaking of CIP cleaning agents
Product monitoring in pipe systems, bottling plants, quality assurance
Leakage monitoring
Its unique hygienic design is certified by EHEDG and 3-A.
Unique hygienic design avoids contamination
With all hygienic certificates required in hygienic applications
Food grade virgin PEEK body without joints nor crevices
Certified biocompatibility according to USP class VI
Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
Compliant with EG 2023/2006 and 1935/2004