The 3500/65 monitor provides 16 channels of temperature monitoring and
accepts both resistance temperature detector (RTD) and isolated tip
thermocouple (TC) temperature inputs. The monitor conditions these inputs and
compares them against user-programmable alarm setpoints.
The monitor is programmed using the 3500 Rack Configuration Software. You
can configure the 16-Channel Temperature Monitor to accept isolated tip
thermocouples, 3-wire RTD, 4-wire RTD, or a combination of TC and RTD inputs.
In Triple Modular Redundant (TMR) configurations, you must install temperature
monitors in groups of 3 adjacent monitors. In this configuration the monitor uses
2 types of voting to ensure accurate operation and to avoid single-point failures
Specifications
Inputs
Signal
Accepts from 1 to 16 RTD or
isolated tip TC transducer signals.
Input
Impedance
Greater than 1 MΩ for each lead
input.
Power
Consumption
3 watts nominal.
Transducers
TCs
Type E
-100 °C to +1000 °C,
(-148 °F to +1832 °F).
Type J
0 °C to +760 °C
(32 °F to +1400 °F).
Type K
0 °C to +1370 °C
(32 °F to +2498 °F).
Type T
-160°C to +400 °C,
(-256 °F to +752 °F).
RTDs
100 Ω 3-wire and 4-
wire platinum RTD
(α = 0.00385):
-200 °C to +850 °C
(-328 °F to +1562 °F).
100 Ω 3-wire and 4-
wire platinum RTD
(α = 0.00392):
-200 °C to +700 °C
(-328 °F to +1292 °F).
120 Ω 3-wire and 4-
wire nickel RTD:
-80 °C to +260 °C
(-112 °F to +500 °F).
10 Ω 3-wire and 4-
wire copper RTD:
-100 °C to +260 °C,
(-148 °F to +500 °F).
Our Advantage:
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Frequently Asked Questions:
Q: Does your goods are new and original?
A: Yes, they are new and original.
Q: How long warranty?
A: One-year warranty.
Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with our sales.