Reliable Engineering Design
• Highly redundant control and power systems
• Extended lifespan of quick-wear heat dissipation parts
• Innovative high thermal capacity radiator to withstand strong impact loads
• Optical fiber cables used for control system and power units for resistance to interference
• Isolation of heat dissipation channels from internal components to protect components and better adapt to environment
Modular Design for Easy Maintenance
• Easy maintenance as no special tools needed
• Enabling all modules to be maintained from the front
• Intelligent fault diagnosis system to locate faults quickly
High Adaptability
• Single-/multi-drive system in the form of units/cabinets with two/four quadrants
• Comprehensive rectifier units: Basic/Smart/PWM rectifier unit
• Strong grid adaptability, support grid wide range of input
• Normal operation under IEC 60721 class 3M5 mechanical conditions
• Precise mechanical design for stronger anti-seismic capability
Customizable Communication Protocols
• Including profibus-DP, CANopen, profinet IO, modbus RTU, modbus TCP, etherCAT, etherNet/ IP, controlNet and deviceNet,etc
• hopeInsight background quick debugging software,including batch parameter settings, fault data downloading and waveform analysis, high-speed oscilloscope and editing
Rich Tools for Human-Machine Interaction
• Configurable LCD keypad panel supporting setting parameters and displaying system information
• Supporting connection to hopeInsight via PC for intelligent fault recording and diagnosis


MAIN PARAMETERS
Model | HD2000 Series Low Voltage Engineering Inverter(Liquid-cooled) | Basic Rectifier | Input voltage | 4:380V~480V,6:500V~690V | Input frequency | (50Hz/60Hz)±6% | Output voltage | Input voltage * 1.32 (Under full-load condition) | Overload capacity | Relative overload at 150% of rated current for 60 seconds, maximum current (Imax), DC overload for 5 seconds,duty cycle of 300 seconds | Operating efficiency | ≥99% Efficiency | Protection eunctions | Protection functions: Overheating protection, soft-start protection, Interlock | protection, and more. | Intelligent rectifier | Input voltage | 4:380V ~ 480V,6: 500V ~ 690V | Input frequency | 47 ~ 63Hz | Output voltage | Input voltage * 1.3 (Under full-load condition) | Overload capacity | Relative overload at 150% of rated current for 60 seconds, maximum current (Imax), DC overload for 5 seconds,duty cycle of 300 seconds | Operating efficiency | ≥98.5% Efficiency | Protection functions | Protection functions: Overheating protection, Overcurrent protection, IGBT pass-through protection, and more | PWM rectifier | Input voltage | 4:380V~480V,6:500V~690V,9:1140V,A:1380V | Input frequency | 47 ~ 63Hz | Output voltage | Input voltage * 1.5 (Under rated conditions) | Overload capacity | Relative overload at 150% of rated current for 60 seconds, maximum current (Imax), DC overload for 5 seconds,duty cycle of 300 seconds | Operating efficiency | ≥98% Efficiency (Including LCL filter unit) | Power factor | Adjustable (Factory setting at 1) | Protection functions | Protection functions: Overheating protection, Overcurrent protection, Overload protection, IGBT pass-through protection, and more. | Inversion | Rated Input voltage | 4:410Vdc~780Vdc,6:550Vdc~1100Vdc,9:1488Vdc~2200Vdc, | A:1488Vdc~2200Vdc | Output voltage | 0 ~ Rectifier AC input voltage | Output frequency | 0 ~ 500Hz | Speed range | V/F:1:50 OLVC:1:200 CLVC:1:1000 | Speed stability | OLVC:0.2% CLVC:0.01% | Speed fluctuation | OLVC:0.2% CLVC:0.1% | Starting torque | OLVC:150%(0.5Hz) CLVC:200%(0Hz) | Torque control | V/F: Unsupported OLVC:Supported CLVC: supported | Torque accuracy | OLVC:5% CLVC:5% | Torque response time | OLVC:5ms CLVC:5ms | Speed response time | OLVC:100ms CLVC:100ms | Dynamic speed drop equivalent | OLVC:0.5%*s CLVC:0.3%*s | Environmental conditions | Temperature | -15℃ ~ +40℃ Without derating, +40℃ ~ +55℃ derating applies | Humidity | 5% ~ 95% Mon-condensing | Altitude | ≤4000m, Derating applies from 2000m to 4000m | Mechanical data | Anti-vibration performance | Complies with IEC 60721-3-3:2002 | Protection level | IP00 / IP20 / IP40 | Safety level | Complies with UL 508C-2004 | Cooling method | Liquid-cooled | | |