HV510 Series High-Performance Inverter
The HV510 series inverters (the "HV510") are Hopewind's new generation of high performance vector inverters. They adopt new high-performance open and closed-loop vector control technology and support asynchronous motor and permanent magnet synchronous motor drive control. Their excellent quality, powerful performance, and high power density design enhance the products' ease of use, reliability, environmental adaptability, functional diversity and application flexibility in industrial scenarios. Their design criteria have been improved and their space minimized, comprehensively upgrading the user experience.
High Safety and Reliability
• Innovative independent air duct design
• Efficient and precise thermal simulation design
• Rigorous temperature rise testing and pre-shipment load aging testing
• Automatic spraying process using conformal coating
• Comprehensive protection functions
High Adaptability
• Wide grid adaptation design
• Built-in C3 filter
• EMC ground disconnection design
• Configured with a built-in brake unit
• Compact type design
Advanced Control Technology
• V/F, OLVC (open-loop vector control), CLVC (closed-loop vector control)
• Supports both asynchronous and synchronous motors
• Supports speed and torque mode control of motors
• Supports switchover between two groups of motor parameters
Excellent Performance
• Accurate auto-tuning ability of motor parameters
• Supports DC braking and dynamic braking
• Heavy load application: 150% for 60s,Light load application: 110% for 60s
• Supports major communication protocols, including Profibus-DP, Profinet IO,etc
• Diversified expansion functions , Supports I/O terminal card, Communication card,etc
Special application functions
• Output frequency up to 1,500 Hz
• Master-slave control function
• Restart upon power failure function
• Position lock function
• Wobble function function
• Encoder running in redundancy function
Autonomous quick debugging
• Background quick debugging software
• Support inverters event recording and 12-channel oscilloscope waveform recording
• Support Parameter editing, status monitoring, fault data and waveform download



Main parameter
Item | Description and Technical Data | Input voltage | 380V (-15%) – 480V (+10%)/three phases | Input power supply frequency | (50Hz/60Hz) ±5% | Input voltage imbalance | ≤ 3% | Output voltage | 0 V to input voltage | Output frequency | 0 Hz–1,500Hz | Motor type | Asynchronous motor, permanent magnet synchronous motor | Control mode | V/F, OLVC (open-loop vector control), CLVC (closed-loop vector control) | Speed range | 1:100 for V/F; 1:200 for OLVC; 1:1000 for CLVC | Startup torque | VF: 100% (0.5Hz); OLVC: 150% (0.25Hz); CLVC: 200% (0Hz) | Torque precision | ±5% (OLVC, above 5Hz), ±3% (CLVC) | Torque ripple | ≤ ±5% under vector control | Speed stabilizing precision | OLVC: 0.2%; CLVC: 0.01% | Torque response | ≤ 5 ms under vector control | Acceleration and deceleration time | 0.0s–3200.0s; 0.0min–3200.0 min | Torque boost | 0.0%–30.0% | Overload capacity | Heavy load application: 150% for 1min/5min, 200% for 3 s/5min Light load application: 110% for 1min/5min, 150% for 10 s/5min | V/F curves | Straight-line type, multi-point type, V/F half separation mode,V/F complete separation mode | Input frequency resolution | Digital setting : 0.01Hz ; analog setting : maximum frequency ×0.025% | Acceleration and deceleration curves | Straight-line and S-curve acceleration and deceleration modes with four types of acceleration and deceleration time and one type of emergency stop deceleration time | Jog control | In some applications, the inverter can run briefly at low speed to test the condition of the equipment | Torque control | Torque control supported during vector control | Simple PLC and multi-segment speed | 16-segment speed operation via control terminals | Built-in PID | Easy implementation of closed-loop process control systems | Virtual IO | 8 groups of virtual VDI/VDO, 3 groups of AI as DI, enabling simple logic control | Overvoltage and overcurrent stall control | Automatic limitation of current and voltage during operation to prevent frequent tripping due to overcurrent or overvoltage | DC braking | Startup DC braking and shutdown DC braking | Pre-excitation | When the inverter starts up, pre-excitation of the motor establishes a magnetic field inside the motor that can effectively improve the torque characteristics of the motor during startup | Overexcitation | This can effectively inhibit the rise of bus voltage during deceleration to avoid frequent overvoltage alerts, and enable quick stop upon power failure | Speed tracking | Speed tracking is supported for both asynchronous and synchronous motors and for both vector control and V/F control | Protection functions | Overvoltage suppression, undervoltage suppression, V/F overcurrent suppression, short to ground, phase loss, detection of excessive speed deviation, overvoltage, overcurrent, undervoltage, overload, over-heating, startup, bus undervoltage, bus overvoltage, etc | | |