PERFORMANCE CHARACTERISTICS
Reliable Engineering Design
.Highly redundant control and power systems
.Extended lifespan of quick-wear heat dissipationparts
.Innovative high thermal capacity radiator to withstand strong impact loads.
.Optical fiber cables used for control system and power units for resistance to interference
.lsolation of heat dissipation channels from internalcomponents to protect components and better adaptto environment
Modular Design for EasyMaintenance
.Easy maintenance as no special tools needed
.Enabling all modules to be maintained from thefront
.Intelligent fault diagnosis system to locate faultsquickly
High Adaptability
.Single-/multi-drive system in the form of units/cabinets with two/four quadrants
.Comprehensive rectifier units: Basic/Smart/PWM rectifier unit
.Strong grid adaptability, support grid wide range of input
.Normal operation under lEC 60721 class 3M5 mechanical conditions
.Precise mechanical desig
Customizable CommunicationProtocols
.Including profibus-DP, CANopen, profinet lO,modbus RTU, modbus TCP etherCAT, etherNet/ lPcontrolNet and deviceNet,etc.
.hopelnsight background quick debugging software,including batch parameter settings, fault data downloading and waveform analysis, high-speed oscilloscope and editing
Rich Tools for Human-Machine Interaction
.Configurable LCD keypad panel supporting setting parameters and displaying system information
.Supporting connection to hopelnsight via PC forintelligent fault recording and diagnosis
Model | HD2000 Series Low Voltage Engineering Inverter(Liquid-cooled) | Basic Rectifier | Input voltage | 4:380V~480V,6:500V~690V | Input frequency | (50Hz/60Hz)±6% | Output voltage | Input voltage * 1.32 (Under full-load condition) | Overload capacity | Relative overload at 150% of rated current for 60 seconds, maximum current (Imax), DC overload for 5 seconds,duty cycle of 300 seconds | Operating efficiency | ≥99% Efficiency | Protection eunctions | Protection functions: Overheating protection, soft-start protection, Interlock | protection, and more. | Intelligent rectifier | Input voltage | 4:380V ~ 480V,6: 500V ~ 690V | Input frequency | 47 ~ 63Hz | Output voltage | Input voltage * 1.3 (Under full-load condition) | Overload capacity | Relative overload at 150% of rated current for 60 seconds, maximum current (Imax), DC overload for 5 seconds,duty cycle of 300 seconds | Operating efficiency | ≥98.5% Efficiency | Protection functions | Protection functions: Overheating protection, Overcurrent protection, IGBT pass-through protection, and more | PWM rectifier | Input voltage | 4:380V~480V,6:500V~690V,9:1140V,A:1380V | Input frequency | 47 ~ 63Hz | Output voltage | Input voltage * 1.5 (Under rated conditions) | Overload capacity | Relative overload at 150% of rated current for 60 seconds, maximum current (Imax), DC overload for 5 seconds,duty cycle of 300 seconds | Operating efficiency | ≥98% Efficiency (Including LCL filter unit) | Power factor | Adjustable (Factory setting at 1) | Protection functions | Protection functions: Overheating protection, Overcurrent protection, Overload protection, IGBT pass-through protection, and more. | Inversion | Rated Input voltage | 4:410Vdc~780Vdc,6:550Vdc~1100Vdc,9:1488Vdc~2200Vdc, | A:1488Vdc~2200Vdc | Output voltage | 0 ~ Rectifier AC input voltage | Output frequency | 0 ~ 500Hz | Speed range | V/F:1:50 OLVC:1:200 CLVC:1:1000 | Speed stability | OLVC:0.2% CLVC:0.01% | Speed fluctuation | OLVC:0.2% CLVC:0.1% | Starting torque | OLVC:150%(0.5Hz) CLVC:200%(0Hz) | Torque control | V/F: Unsupported OLVC:Supported CLVC: supported | Torque accuracy | OLVC:5% CLVC:5% | Torque response time | OLVC:5ms CLVC:5ms | Speed response time | OLVC:100ms CLVC:100ms | Dynamic speed drop equivalent | OLVC:0.5%*s CLVC:0.3%*s | Environmental conditions | Temperature | -15℃ ~ +40℃ Without derating, +40℃ ~ +55℃ derating applies | Humidity | 5% ~ 95% Mon-condensing | Altitude | ≤4000m, Derating applies from 2000m to 4000m | Mechanical data | Anti-vibration performance | Complies with IEC 60721-3-3:2002 | Protection level | IP00 / IP20 / IP40 | Safety level | Complies with UL 508C-2004 | Cooling method | Liquid-cooled | | |