Self-patented Low Voltage VFD Inverter 380V 3 Phase 250kw For Glass processing Industry
FPR500A Product specifications
Item | Specifications | |
Basic function | Over load capability | G type:150% rated current 60s;180% rated current 3s |
P type:120% rated current 60s;150% rated current 3s | ||
Torque boost | Auto torque boost function; Manual torque boost 0.1%~30.0% | |
V/F curve | Linear V/F, multi-point V/F and square V/F curve(power of 1.2,1.4,1.6,1.8,2) | |
V/F separation | 2 ways: separation and semi-separation | |
Acc./dec curve | Straight line or S curve acceleration and deceleration mode, | |
Four kinds of acceleration and deceleration time. Acceleration and deceleration time range from 0.0s to 6500.0s | ||
DC braking | DC braking frequency:0.00Hz to maximum frequency. Braking time:0.0s to 36.0s | |
Brake current value:0%-100% | ||
Jog control | Jog frequency range:0.00Hz~50.00Hz; | |
Jog acceleration/deceleration:0.0s~6500.0s. | ||
Simple PLC | It can realize at maximum of 16 segments speed | |
Basic function | Multiple segment speed running | Running via the built-in PLC or control terminal. |
Built-in PID | It is easy to realize process-controlled closed loop control system. | |
Auto voltage regulation (AVR) | It can keep constant output voltage automatically in the case of change of network voltage. | |
Over-voltage/current stall control | It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process. | |
Quick current limit | Minimize the over-current fault, protect normal operation of the AC Drive. | |
Torque limit & control | "Excavators" characteristics, automatically limit torque during operation, prevent frequent over-current tripping. Closed loop vector mode can realize the torque control. | |
Personalized function | Instantaneous stop non-stop | When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC Drive keep running in a short period of time. |
Rapid current limit | To avoid AC Drive frequent over-current fault. | |
Timing control | Timing control function:set time range 0Min~6500.0Min. | |
Running | Command source | Operation panel reference, control terminal reference and serial communication port reference. These channels can be switched in various modes. |
Frequency source | There are totally eleven types of frequency sources, such as digital reference, analog voltage reference , analog current reference, pulse reference, MS speed, PLC, PID and serial port reference. | |
Input terminal | 3 digital input terminals. | |
1 analog input terminals. | ||
1 supporting 0-10V voltage input or 0~20mA current input terminal. | ||
Output terminal | ||
1 relay output terminals. | ||
Keyboard operation | Keyboard potentiometer | Equipped with keyboard potentiometer or coding potentiometer. |
Keyboard operation | Protection function | It can implement power-on motor short-circuit detection, input /output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection.
|
Environment | Using place | Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | Below 1000m | |
Ambient temperature | -10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃) | |
Humidity | Less than 95%RH,without condensing | |
Vibration | Less than 5.9m/s (0.6g) |
Field Application Photos:
Facilities: