FPR High-performance closed-loop vector converter
Power class
Single-phase 220v±15% 0.4-2.2kw
Three-phase 380V±15% 0.75-315kw
Product introduction
FPR500 series relies on TI company's DSP dual-core professional control motor chip, which supplies the international leading vector control algorithm to realize the real high-precision flux vector torque control. It has built-in pg vector control (VC), pg-free vector control (SVC), and V/F control modes, which are widely applied to high-speed control accuracy, rapid torque response, and high performance at low frequency. The integration of torque control, speed control, and position control can meet the high-performance requirements of customer applications. And, FPR 500 has the ability to exceed the anti-trip performance of similar products and adapt to the severe power grid, ambient temperature, humidity, and dust, greatly improving the reliability of products.
Technical characteristics
Drive motor type:Ac asynchronous motor, Ac permanent magnet synchronous motor
Four control modes:PG vector control(FVC), PG-free vector control(SVC),
V / F control, Torque control
Speed control range:PG vector control(FVC)1:1000
PG- free vector control(SVC)1:200
V / F control 1:50
Speed control accuracy:PG vector control (FVC)±0.2%
PG- free vector control (SVC)±0.5%
Starting torque:PG vector control(FVC):180 % rated torque/0.01Hz
PG- free vector control (SVC)150% rated torque/0.25Hz
Torque control accuracy:PG vector control (FVC)±5%
PG- free vector control (SVC)±8%
Multi-motor switching: Two groups of motor parameters can realize the switching control of the two motors.
Motor overheating protection:Optional IO expansion card, analog A / 3 can accept input from the motor temperature sensor
Supports multiple encoders:Supports differential, open collector, uvw, rotary transformer, sine and cosine encoder
Torque limitation and control: the "excavator" feature, automatically limits the torque during operation to prevent frequent overcurrent trips. Closed-loop mode can realize torque control.
Products Specifications:
Basic Function | Specification | |
Maximum output frequency | 0~500Hz | |
Carrier frequency | 0.5kHz~16.0kHz;According to the load characteristics, carrier frequency can be adjusted automatically | |
Input frequency | Range :47~63Hz | |
Control mode | V/F Open/closed loop vector control(SVC/FVC) | |
Speed range | 1:50(Vector mode 0 ) 1Hz/150% rated torque | |
Overload capability | G type:150% rated current for 60s; 180% rated current for 3s P type:120% rated current for 60s; 150% rated current for 3s | |
Torque boost | Auto Torque boost Manual Torque boost; 0.1%~30.0%. | |
V/F curve V/F | Four modes : Line , Multi-point , Square V/F curve, V/F separation | |
Jog control | Jog frequency range:0.00Hz to F0-10(Max frequency) | |
Accelerate/Decelerate curve | Line or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range of Acc/Dec Time0.0~65000.00s. | |
DC brake | DC brake frequency: 0.00Hz to Maximum frequency brake time: 0.0 to 36.0s brake current value: 0.0 to 100% | |
Simple PLC, Multi-speed | 16-speed operating through built-in PLC or control terminal | |
Built-in PID | Close loop control system can be formed easily by using PID | |
Automatic voltage regulating (AVR) | Output voltage is regulated when voltage of the power network changes | |
Overvoltage and over current stall control | During operation automatically limits the inverter output current and bus voltage, to prevent fan over current and overvoltage trip. | |
Rapid current limiting function | Minimizing flow failures, protect the normal operation of the inverter | |
Instantaneous stop non-stop | Load feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted. | |
Speed tracking start | For high-speed rotation of the motor speed identification, impact- free smooth start | |
Rapid current limit | Rapid software and hardware limiting technology to avoid frequent converter over current fault. | |
Virtual IO | Five sets of virtual DO, five sets of virtual DI, enables easy logic control. | |
Timing Control | Timing control: set the time range 0.0Min~6500.0Hour | |
Multi-motor switch | Two independent motor parameters, enabling two motors switching control | |
Bus Support | Two independent Modbus communication, CAN-Link | |
Command source | Given the control panel, control terminal, serial communication port given. It can be switched by a variety of ways. | |
Torque boost | Auto Torque boost Manual Torque boost ; 0.1%~30.0%. | |
Frequency source | Nine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways. | |
Auxiliary frequency source | Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary frequency tuning, frequency synthesis. | |
Input terminal | Six digital input terminals, one only supports 50khz high pulse input Two analog input terminals, one support 0V~10V voltage input One support 0 ~ 10V voltage input or 0 ~ 20mA current input | |
Output terminal | One high-speed pulse output terminal (optional open collector type), support of square wave 0 ~ 50kHz signal output One digital output terminal One relay output terminals Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output | |
Display and operation | ||
LED display | Display parameters and status information | |
The key lock and function selection | Achieve some or all of the keys locked, scope definition section keys to prevent misuse. | |
Protection function | Input/output phase failure protection ,Overcurrent protection ;Over voltage protection; Undervoltage protection; Overheat protection ; Overload protection | |
Options | Brake assembly, PG card | |
Environment | ||
Application environment | In-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt . | |
Altitude | Lower than 1000m | |
Vibration | Less than 5.9m/s(0.6g) |