Specifications
Brand Name :
SHC
Model Number :
SC-CSH
Certification :
CNAS、TUV、ITS、CSA、BV、SGS (cost additional)
Place of Origin :
China
MOQ :
1 unit
Price :
USD50-2000 unit
Payment Terms :
T/T, Western Union, MoneyGram, L/C
Supply Ability :
999 units per month
Delivery Time :
in 15 working days
Packaging Details :
carton
Product name :
Calibration Device Impact Testing Machine For Spring Hammer
Function :
Calibration Device
Accuracy :
0.01J
The maximum measuring range :
0-2J
Impact energy :
Max. 2J
The weight :
Copper weight cover(2J)
Guide groove diameter :
51mm
Reference :
IEC 60068-2-75 figure B1
Description

Calibration Device Impact Testing Machine For Spring Hammer

Technical parameters:

Accuracy 0.01J
The maximum measuring range 0-2J
Impact energy Max. 2J
The weight Copper weight cover(2J)
Guide groove diameter 51mm
Pendulum Steel
Diameter pendulum 20mm
Length pendulum 635mm ± 2,5mm
Pendulum H 120mm ± 2mm
Pendulum D 20mm ± 0,5mm
Pendulum W 4mm ± 0,01mm
The energy loss of the pendulum <0.002J
Release device Ac. Mechanic
Trigger distance >30mm
Reference IEC 60068-2-75 figure B1

Confirms:

IEC60068-2-75

Product details:
As the requirements shown in the IEC60068-2-75, this calibration device is used to test the impact energy of the spring hammer.

It is the special equipment for the laboratory.

Because it is difficult to measure directly for the offered energy of the calibrated spring hammer, the calibration principle of this device is by comparing the energy which is calculated by the mass of the pendulum and drop height.

The highest resolution capability of this device is 0.01J. The release mechanism is improved in the design, it can maximum reduce vibration affect on the test when the the spring hammer lease, the pendulum rod and aerospace bearing are made of imported good quality steel, so that to improve the precision and stability of the device.

The highest resolution capability of this device is 0.01J. The release mechanism is improved in the design, it can maximum reduce vibration affect on the test when the the spring hammer lease, the pendulum rod and aerospace bearing are made of imported good quality steel, so that to improve the precision and stability of the device.

Procedure for the calibration of spring hammers:

B.1 Principle of calibration

The principle of this calibration procedure is to compare the energy provided by a spring hammer, which is difficult to measure directly, to the energy of a pendulum, calculated from its mass and height of fall.

B.2 Construction of the calibration device

The assembled calibration device is shown in figure B.1. Apart from the frame, the main parts are a bearing “a”, a drag pointer “b ”, a pendulum “c”, a release base “d” and a release device “e”.

The main part of the calibration device is the pendulum “c” shown in figure B.2. To the lower end of this pendulum is fixed a steel spring with the details shown in figure B.3. The spring is of spring steel, requiring no special treatment, and is rigidly fixed to the pendulum “c”.

Figure B.4 shows some parts on a large scale

It should be noted that this spring is designed for calibrating spring hammers having characteristics as defined in table 1 for energy values equal to or less than 1 J. For calibrating spring hammers having characteristics as defined for 2 J, the spring of the pendulum of the calibrating device would need to be of a different design.

In order to obtain suitable friction characteristics of the pointer, a piece of thick woven cloth is placed between the metal surfaces of the bearing, the piano wires being bent in such a way that a small force is exerted against the cloth.

Because the release device is removed during the calibration of the calibration device, the release device is fixed to the release base by means of screws.

B.3 Method of calibration of the calibration device

The calibration of the calibration device is effected by using a calibration striking element “g” taken from a spring-hammer, as shown in figure B.5. Before calibration, the release device is removed from the calibration device.

The calibration striking element is suspended by four linen threads “h” from suspension points situated in a horizontal plane, 2000 mm above the point of contact between the pendulum and the calibration striking element when the latter is in its rest position. The calibration striking element is allowed to swing against the pendulum and the point of contact under dynamic conditions, point “k”, shall be not more than 1 mm below the point of contact in the rest position. The suspension points are then raised over a distance equal to the difference between both contact points.

Send your message to this supplier
Send Now

2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment

Ask Latest Price
Brand Name :
SHC
Model Number :
SC-CSH
Certification :
CNAS、TUV、ITS、CSA、BV、SGS (cost additional)
Place of Origin :
China
MOQ :
1 unit
Price :
USD50-2000 unit
Contact Supplier
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment
2J Impact Testing Apparatus , Spring Hammer Calibration Testing Equipment

Guangzhou Shice Equipment Co., Ltd.

Active Member
5 Years
guangzhou
Since 2016
Business Type :
Manufacturer
Total Annual :
1000000-3000000
Employee Number :
>100
Certification Level :
Active Member
Contact Supplier
Submit Requirement