Specifications
Brand Name :
ITI-LINK
Model Number :
ITI-CT7SF-008
Place of Origin :
SHENZHEN
Certification :
UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
MOQ :
1000pcs
Packaging Details :
Wooden shaft packaging 40*26*20cm Outer box size:42*42*22cm
Delivery Time :
15-45 Days
Payment Terms :
T/T
Supply Ability :
1000pcs/day
Jacket Material :
PVC
Frequency :
600MHz
Conductor Material :
Copper
Shielding Type :
SFTP
Length :
1000Ft
Cable Type :
CAT7
Jacket Color :
Purple
Conductor Size :
23AWG
Description

Cat7 SFTP 23AWG CPR Dca-s2,d2,a1 Purple PVC Cable for 10Gbps Network 1000FT

Product Description:

1.The Cat7 SFTP 23AWG CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network 600MHz is shielded with SFTP (Shielded Foiled Twisted Pair), which offers outstanding protection against electromagnetic interference (EMI) and radio frequency interference (RFI). This shielding not only allows you to maintain seamless internet connectivity even when surrounded by various electronic devices but also ensures the utmost security and confidentiality of your data. Additionally, it complies with the CPR (Construction Products Regulation) standard and has the specific Dca-s2,d2,a1 characteristics, which enhance its performance and safety in different networking environments.


2.It exhibits backward compatibility with earlier Ethernet standards, presenting a flexible solution for all your networking requirements. Cat7 Ethernet cables are engineered to support cutting-edge technologies such as 10 Gigabit Ethernet, making them highly suitable for high-performance networks. With a length of 1000Ft, it provides extensive reach for various installation scenarios.


3.The conductor size of this cable is 23AWG, indicating a thicker conductor in comparison to many other Ethernet cables. This thicker conductor leads to reduced resistance and minimal signal loss, thereby guaranteeing a faster and more dependable internet connection. The conductor material is copper, renowned for its exceptional conductivity and durability. Copper is favored for Ethernet cables due to its flexibility, ease of handling, and low resistance.


4.The jacket color of this cable is purple, which facilitates easy identification and differentiation from other cables. The PVC jacket of an Ethernet cable safeguards the internal components from environmental elements like moisture, dust, and physical damage. The purple color imparts a professional and stylish appearance, making it an excellent choice for use in offices, data centers, and other commercial settings.


5.In conclusion, the Cat7 SFTP 23AWG CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network 600MHz is a top-notch Ethernet cable that delivers high-speed data transfer rates, excellent shielding, and remarkable durability. It is the perfect option for individuals seeking fast and reliable internet connectivity in their homes or offices. Place your order for this cable today and relish the pinnacle of high-speed networking!

Features:

  • Product Name: Cat7 SFTP 23AWG CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network 600MHz
  • Length: 1000Ft
  • Conductor Material: Copper
  • Cable Type: CAT7
  • Jacket Color: Purple
  • Conductor Size: 23AWG

The Cat7 SFTP 23AWG CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network 600MHz is a high-speed Ethernet cable. It's great for quickly and efficiently transferring large files, suitable for connecting various network devices. With a 1000Ft length, it can reach far. The 23AWG copper conductor ensures durability and aids signal transmission. Complying with CPR and having Dca-s2,d2,a1 features, it meets high-speed network needs. The SFTP shielding resists interference, and the purple PVC jacket protects and is easy to identify. Ideal for home and office use where stable, high-speed connections matter.

Technical Parameters:

Product Attribute Description
Cable Type Cat7 Ethernet Cable
Shielding Type SFTP Cat7 Cable
Conductor Material Copper
Conductor Size 23AWG
Jacket Material PVC
Jacket Color Purple
Frequency 600MHz
Length 1000Ft

Product Description:

Cat7 SFTP 23AWG CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network 600MHz

Rev.: A ECN Description:
Construction Item Description Electrical Property

Conductor

Material

Bare Solid Copper(elongation:

19-24%)

Conductor Resistance at 20°C ≤ 9.5 Ω / 100m
OD 23 AWG Resistance unbalance within a pair ≤ 2%

Insulation

Material PE Skin-Foam-Skin Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

>1500 MΩ / 100m

OD 1.33 ±0.01 mm Mutual capacitance 5600 pF / 100m MAX
Average THK 0.37mm Capacitance unbalance pair to ground at 800Hz or 1 kHz ≤ 160 pF / 100m

Color

1p: white + 2 blue stripes & blue Characteristic impedance at 100MHz 100 ± 15 Ω

2p: white + 2 orange stripes &

orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min

No breakdown

3p: white + 2 green stripes & green Mechanical Property
4p: white + 2 brown stripes & brown

insulation

elongation before aging ≥ 300%

Pair Twist

Lay & Direction

1p: S=19.0 mm (28%) tensile strength before aging ≥12 MPa
2p: S=23.5 mm (31%) elongation after aging ≥ 150 %
3p: S=21.5 mm (33%) tensile strength after aging ≥10.5 MPa
4p: S=25.0 mm (36%)

jacket

elongation before aging ≥ 125 %
OD / tensile strength before aging ≥ 10 MPa

Inner Assemble

Lay S=90 ± 5 mm elongation after aging ≥ 100 %
Direction according to the drawing tensile strength after aging ≥ 8 MPa
OD / Packing

Filler

Ripcord 3*250D Drum NA
Drain Wire /

Pair Shield

Shield Pair Shield

Construction /
Material Polyester/Aluminium (PET/ALU)
Coverage ≥ 115%

Braid

Material ɸ 0.12mm Aluminum-magnesium braided
Coverage ≥ 40%

Jacket

Material PVC, 60P, -20~75℃
Hardness 81± 3
OD 8.1 ± 0.2
Average THK 0.55 ~ 0.65

Color

Purple
Marking Color black
Marking

according to the customer's

requirements

Electrical Properties
Conductor Resistance at 20°C NF EN 50289-1-2 / IEC 60189-1 ≤ 9.5 Ω / 100m
Resistance unbalance within a pair NF EN 50289-1-2/ IEC 60708 ≤ 2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min

NF EN 50289-1-3 / IEC 61196-1-105

No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

NF EN 50289-1-4 / IEC 60885-1

>1500 MΩ / 100m
Mutual capacitance NF EN 50289-1-5 /IEC 60189-1 5600pF / 100m MAX
Capacitance unbalance pair to ground at 800Hz or 1 kHz NF EN 50289-1-5 / IEC 60189-1 ≤ 160 pF / 100m
Characteristic impedance at 100MHz NF EN 50289-1-11/ IEC 61156-1 100 ± 15 Ω
Spark Test UL444 2000 ± 250VOC

Transmission Properties
CAT7 ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013

No.

Frequency

Attenuation (Max)

Propagation Delay

(Max)

Propagation Delay Skew

(Max)

Return Loss (Min)

NEXT (Min)

PS NEXT (Min)

EL-FEXT (Min)

PS EL-FEXT (Min)

MHz dB/100m ns/100m ns/100m dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m)
1 4 3.74 552 25 23.00 78.0 75.30 78.0 75.00
2 8 5.24 547 25 24.50 78.0 75.0 75.90 72.90
3 10 5.86 545 25 25.00 78.0 75.0 74.00 71.00
4 16 7.41 543 25 25.00 78.0 75.0 69.90 66.90
5 20 8.29 542 25 25.00 78.0 75.0 68.00 65.00
6 25 9.29 541 25 24.30 78.0 75.0 66.00 63.00
7 31.25 10.41 540 25 23.60 78.0 75.0 64.10 61.10
8 62.5 14.88 539 25 21.50 75.50 72.40 55.10 55.10
9 100 19.20 538 25 20.10 72.40 69.40 54.00 51.00
10 150 23.56 537 25 18.90 69.80 66.80 50.20 47.20
11 200 27.74 536 25 18.00 67.80 64.90 48.00 45.00
12 250 30.97 536 25 17.30 66.40 63.40 46.00 43.00
13 300 34.19 536 25 17.30 65.20 62.20 44.50 41.50
14 600 50.10 536 25 17.30 60.70 57.70 38.40 35.40
15 800 58.92 535 25 17.30 58.90 55.90 35.90 32.90
16 1000 66.93 535 25 17.10 57.40 54.40 34.00 31.00

Applications:

One of the main applications of this Cat7 Lan Cable, which is a Cat7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network, lies in Ethernet networks. Thanks to its 23AWG conductor size, this cable can achieve high-speed data transfer rates of up to 10Gbps, making it highly suitable for streaming video, gaming, and other bandwidth-intensive tasks. The SFTP shielding, which is a key feature, effectively reduces interference and crosstalk, thereby ensuring a more stable and reliable network connection. This is especially crucial in environments with multiple electronic devices or strong electromagnetic fields.

Whether you are establishing a home network, enhancing your office infrastructure, or interconnecting multiple devices in a data center, the ITI - LINK Cat7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network is a versatile and dependable option that can fulfill your requirements. This cable demonstrates compatibility with a broad spectrum of networking equipment and can be deployed in diverse scenarios. For instance:

  • In residential and commercial buildings, it can support seamless connectivity for various smart home devices and office workstations, ensuring smooth operation of daily applications such as video conferencing and large file transfers.

  • In schools and universities, it can handle the heavy network traffic generated by a large number of students and faculty members accessing online resources, educational software, and conducting research activities.

  • In hospitals and healthcare facilities, the cable's reliability and security features, enhanced by its CPR compliance and Dca-s2,d2,a1 characteristics, are vital. It can support the transmission of critical patient data, imaging files, and real-time monitoring information without interruption or data loss.

  • In data centers and server rooms, where high-density cable installations are common, the 1000Ft length of the cable provides flexibility in layout and connection. The cable's ability to maintain stable performance under high data load and in the presence of other cables' interference is essential for the continuous operation of servers and network infrastructure.

  • In industrial and manufacturing environments, the cable's durability and resistance to environmental factors, combined with its interference shielding capabilities, enable it to function reliably in harsh conditions. It can support the communication between industrial control systems, sensors, and automation equipment, ensuring the smooth running of production processes.


In any of these scenarios, the ITI - LINK Cat7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Purple PVC Cable for Stable Network can establish a fast, stable, and secure network connection that can accommodate even the most demanding applications and workloads.

Purple Cat7 SFTP 23AWG CPR Dca-S2 D2 A1 PVC Cable For 10Gbps Network 1000FT

FAQ:

Q: What is the brand name of this product?

A: The brand name of this product is ITI-LINK.

Q: What is the model number of this product?

A: The model number of this product is ITI-CT7SF-008.

Q: Where is this product manufactured?

A: This product is manufactured in SHENZHEN.

Q: What is the maximum data transfer rate of this cable?

A: This cable is a CAT7 cable and has a maximum data transfer rate of 10Gbps.

Q: Is this cable suitable for outdoor use?

A: No, this cable is not suitable for outdoor use.

Q: How are Cat7 shielded network cables grounded?
A: Generally, single ended grounding is adopted: one end of the shielded wire is grounded and the other end is suspended.

Send your message to this supplier
Send Now

Purple Cat7 SFTP 23AWG CPR Dca-S2 D2 A1 PVC Cable For 10Gbps Network 1000FT

Ask Latest Price
Watch Video
Brand Name :
ITI-LINK
Model Number :
ITI-CT7SF-008
Place of Origin :
SHENZHEN
Certification :
UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
MOQ :
1000pcs
Packaging Details :
Wooden shaft packaging 40*26*20cm Outer box size:42*42*22cm
Contact Supplier
video
Purple Cat7 SFTP 23AWG CPR Dca-S2 D2 A1 PVC Cable For 10Gbps Network 1000FT
Purple Cat7 SFTP 23AWG CPR Dca-S2 D2 A1 PVC Cable For 10Gbps Network 1000FT
Purple Cat7 SFTP 23AWG CPR Dca-S2 D2 A1 PVC Cable For 10Gbps Network 1000FT

Integrity Cable Co., Limited

Verified Supplier
1 Years
shenzhen
Since 2014
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Seller
Total Annual :
100,000,000-150,000,000
Employee Number :
100~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement