Specifications
Brand Name :
ITI-LINK
Model Number :
ITI-CTSF7A-006
Place of Origin :
SHENZHEN
Certification :
UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
MOQ :
1000pcs
Payment Terms :
T/T
Supply Ability :
2000pcs/day
Delivery Time :
15-45 Days
Packaging Details :
Wooden shaft packaging 32*22*12cm Outer box size: 37*37*24cm
Cable Type :
SFTP
Conductor Material :
Copper
Color :
Orange
Category :
CAT7A
Frequency :
1000 MHz
Cable Length :
305 Meters
Conductor Size :
23 AWG
Jacket Material :
PVC
Description

Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center

Product Description:

1.The Cat7A SFTP Shielded Ethernet Orange Cable is a top - notch networking solution tailored for the rigorous demands of data centers. With a 23 AWG conductor size, this cable is engineered to offer outstanding performance and unwavering reliability during high - speed data transfer.

2.Measuring 305 meters in length, this orange - hued cable provides extensive flexibility for installation within large - scale data center environments. Whether it's for connecting servers, storage devices, or networking switches, the ample length ensures seamless connectivity, meeting all your data center's cabling requirements.

3.Operating at an impressive 1000 MHz frequency and boasting a 10Gbps data transfer rate, the Cat7A SFTP Shielded Ethernet Orange Cable guarantees swift data transmission with minimal interference. This makes it an ideal fit for data centers where reliable and ultra - fast data transfer is the lifeblood of operations.

4.The cable is encased in a durable PVC jacket. PVC offers excellent protection against physical damage, abrasion, and moisture, ensuring the cable's longevity even in the harsh conditions often found in data centers. It also provides flexibility, facilitating easy installation around racks and through conduits.

5.Constructed using pure copper conductors, this cable offers superior conductivity and signal quality. Copper, being highly conductive, enables efficient data transfer while minimizing signal loss, which is crucial for maintaining high - performance networking within the data center.

6.Overall, this Cat7A SFTP Shielded Ethernet Orange Cable, also recognized as a Cat7A Ethernet Cable or CAT7 LAN Cable, serves as a reliable and high - speed networking solution specifically designed for data centers. Its robust build, high - frequency capabilities, and use of quality materials like pure copper and PVC make it well - equipped to handle the most demanding networking requirements of modern - day data centers.

Technical Parameters:

Jacket Material

PVC

Category

CAT7A

Cable Type

SFTP

Cable Length

305 Meters

Conductor Material

Copper

Color

Orange

Conductor Size

23 AWG

Frequency

1000 MHz

Product Description: Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center
Rev.: A ECN Description:
Construction Item Description Electrical Property

Conductor

Material

Bare Solid Copper(elongation:

19-24%)

Conductor Resistance at 20°C ≤ 9.5 Ω / 100m
OD 23AWG Resistance unbalance within a pair ≤ 2%

Insulation

Material PE Skin-Foam-Skin Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

>1500 MΩ / 100m

OD 1.45 ±0.01 mm Mutual capacitance 5600 pF / 100m MAX
Average THK 0.42 mm Capacitance unbalance pair to ground at 800Hz or 1 kHz ≤ 160 pF / 100m

Color

1p: white + 2 blue stripes & blue Characteristic impedance at 100MHz 100 ± 15 Ω

2p: white + 2 orange stripes &

orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min

No breakdown

3p: white + 2 green stripes & green Mechanical Property
4p: white + 2 brown stripes & brown

insulation

elongation before aging ≥ 300%

Pair Twist

Lay & Direction

1p: S=19.0 mm (28%) tensile strength before aging ≥12 MPa
2p: S=23.5 mm (31%) elongation after aging ≥ 150 %
3p: S=21.5 mm (33%) tensile strength after aging ≥10.5 MPa
4p: S=25.0 mm (36%)

jacket

elongation before aging ≥ 150 %
OD / tensile strength before aging ≥ 13.5 MPa

Inner Assemble

Lay S=90 ± 5 mm elongation after aging ≥ 125 %
Direction according to the drawing tensile strength after aging ≥ 12.5 MPa
OD / Packing

Filler

Ripcord / Drum NA
Drain Wire /

Pair Shield

Shield Pair Shield
Construction /
Material Polyester/Aluminium (PET/ALU)
Coverage ≥ 115%

Braid

Material ɸ 0.12mm Aluminum-magnesium braidedr
Coverage ≥ 40%

Jacket

Material PVC, 50P, -20~75℃
Hardness 81± 3
OD 8.5 ± 0.2
Average THK 0.60 ~ 0.70

Color

according to the customer's requirements
Marking Color Orange
Marking according to the customer's requirements

Transmission Properties
CAT7A ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013

No.

Frequency

Attenuation (Max)

Propagation Delay

(Max)

Propagation Delay Skew

(Max)

Return Loss (Min)

NEXT (Min)

PS NEXT (Min)

EL-FEXT (Min)

PS EL-FEXT (Min)

MHz dB/100m ns/100m ns/100m dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m)
1 4 3.7 552 25 23.0 78.0 75.0 78.0 75.0
2 8 5.2 547 25 24.5 78.0 75.0 77.2 74.2
3 10 5.8 545 25 25.0 78.0 75.0 75.3 72.3
4 16 7.3 543 25 25.0 78.0 75.0 71.2 68.2
5 20 8.2 542 25 25.0 78.0 75.0 69.3 66.3
6 25 9.2 541 25 24.3 78.0 75.0 67.3 64.3
7 31.25 10.3 540 25 23.6 78.0 75.0 65.4 62.4
8 62.5 14.6 539 25 21.5 78.0 75.0 59.4 56.4
9 100 18.5 538 25 20.1 75.4 72.4 55.3 52.3
10 200 26.5 537 25 18.0 70.9 67.9 49.3 46.3
11 250 29.7 536 25 17.3 69.4 66.4 47.3 44.3
12 300 32.7 536 25 17.3 68.2 65.2 45.8 42.8
13 400 38.0 536 25 17.3 66.4 63.4 43.3 40.3
14 500 42.8 536 25 17.3 64.9 61.9 41.3 38.3
15 600 47.1 535 25 17.3 63.7 60.7 39.7 36.7
16 1000 61.9 535 25 15.1 60.4 57.4 35.3 32.3

Electrical Properties
Conductor Resistance at 20°C NF EN 50289-1-2 / IEC 60189-1 ≤ 9.5 Ω / 100m
Resistance unbalance within a pair NF EN 50289-1-2/ IEC 60708 ≤ 2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min

NF EN 50289-1-3 / IEC 61196-1-105

No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

NF EN 50289-1-4 / IEC 60885-1

>1500 MΩ / 100m
Mutual capacitance NF EN 50289-1-5 /IEC 60189-1 5600pF / 100m MAX
Capacitance unbalance pair to ground at 800Hz or 1 kHz NF EN 50289-1-5 / IEC 60189-1 ≤ 160 pF / 100m
Characteristic impedance at 100MHz NF EN 50289-1-11/ IEC 61156-1 100 ± 15 Ω
Spark Test UL444 2000 ± 250VOC

Applications:

1.The Cat7A SFTP Shielded Ethernet Orange Cable is a premium - grade Ethernet cable specifically engineered for the intricate demands of data center networking applications. With its Cat7A classification, this cable offers unparalleled performance and unwavering reliability in the most challenging networking environments.

2.One of the primary application scenarios for the [Brand Name] Cat7A cable is in high - speed data transfer within data centers, where a stable and ultra - fast connection is of utmost importance. Whether it's for interconnecting servers, storage arrays, or high - performance switches in a data center, this cable guarantees seamless data transmission with minimal interference, enabling the efficient operation of data - intensive applications.

3.The distinct orange color of the cable makes it highly visible and easy to identify within the complex wiring systems of a data center. This not only simplifies cable management but also adds a touch of uniqueness. The 23 AWG pure copper conductors inside the cable are designed to ensure rapid and efficient data flow, maintaining high signal integrity. This makes it an ideal choice for Cat7A Lan Cable installations in data centers, where the quality of data transmission directly impacts business operations.

4.Manufactured with precision, the Cat7A cable is crafted to meet the strictest quality standards. It features a durable PVC jacket that not only protects the internal components from physical damage but also provides resistance to environmental factors commonly found in data centers, such as dust and moisture. Its SFTP design offers enhanced shielding, effectively minimizing crosstalk and external interference. This ensures a stable and secure connection, even in the presence of high - level electromagnetic noise that is typical in data center environments.

5.Whether you are in the process of upgrading your existing data center network infrastructure to handle the increasing demands of big data and cloud computing or setting up a new state - of - the - art data center from the ground up, the [Brand Name] Cat7A SFTP Shielded Ethernet Orange Cable is a versatile and reliable solution. It offers superior performance and long - term durability, making it a trusted choice for all your Cat7A Ethernet Cable requirements in data center networking. Experience seamless and high - speed networking connectivity with this exceptional cable.

Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center

FAQ:

Q: What is the brand name of this SFTP CAT7A Cable?

A: The brand name of this cable is ITI-LINK.

Q: What is the model number of this SFTP CAT7A Cable?

A: The model number of this cable is ITI-CTSF7A-006.

Q: Where is this SFTP CAT7A Cable manufactured?

A: This cable is manufactured in SHENZHEN.

Q: What type of shielding does this SFTP CAT7A Cable have?

A: This cable has SFTP (Screened Foiled Twisted Pair) shielding for enhanced performance.

Q: What is the length of this SFTP CAT7A Cable?

A: This cable is 1000 feet (approximately 305 meters) in length.

Send your message to this supplier
Send Now

Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center

Ask Latest Price
Watch Video
Brand Name :
ITI-LINK
Model Number :
ITI-CTSF7A-006
Place of Origin :
SHENZHEN
Certification :
UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
MOQ :
1000pcs
Payment Terms :
T/T
Contact Supplier
video
Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center
Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center
Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center
Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center

Integrity Cable Co., Limited

Verified Supplier
1 Years
shenzhen
Since 2014
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Seller
Total Annual :
100,000,000-150,000,000
Employee Number :
100~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement