Product Name :
120A Mechanical Latching Relay
Rated Load :
120A 250VAC
Contact Form :
1A/B
Contact Material :
AgSnO2
Max. Switching Voltage :
277VAC
Max. Switching Current :
120A
Max. Switching Power :
33240 VA
Contact Resistance :
<2mΩ
Pick-up & Release Time :
30ms
Electrical Endurance :
10000 Cycles
Mechanical Endurance :
100000 Cycles
Temp.Rise :
≤55K When Ambient 40℃
Usage :
General Purpose,Protective
Description

120A 24V Dual Coil Non UC3 Certified latching Relay Switch for Street Lamp

1.Overview:

Max.Switching Current:120A

Rated Coil Consumption:1.5/3W(20ms)

Dimension:42*35*21.5mm

IEC62055-31 UC3 Certified

● Widely used for smart meter,smart grid,solar panel,EV charger,switching cabinet,RCCB/RMB,lighting systerm

circuit protection,electrical machine

2.Specification:

Dimension(mm)

42×35×21.3

Weight ( g ) ≈33g
Contact Arrangement 1A/1B
Contact Material AgSnO2
Ambient Temperature -40~+70℃
Ambient Humidity 45%~90%RH
Vibration 10~55Hz,1.5mm(DA)
Nominal Voltage 6~48VDC
Power Consumption Single Coil:2.0W, Dual Coil:4.0W
Max. Switching Voltage 250VAC
Max. Switching Current 120A
Max. Switching Power

33240 VA

Contact Resistance

<2.0 mΩ

Insulation Resistance 1000MΩ(DC 500V)
Dielectric Creepage 8mm
Dielectric Strength Across Open Contact >2000VAC 1min
Coil to Contact >4000VAC 1min
Electrical Life >10,000cycles
Mechanical Life >100,000cycles
Picking-up & Release Time ≦20ms
Pulse Duration ≧100ms
Functional Shock Resistance 10G
Destructive Shock Resistance 100G

3.Application Notes:

3.1. Suggestions of relays input

(1) Polarity-Please check the polarity inside of our technical specification, if single coil then”+ -” or “- +”are fine, you can change it by one pulse.

If double coil then it‘s necessary to confirm “-+-” or “+-+“before leaving the our factory.

(2) Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance,

if 1.5 time or 2 times of value or lower driving condition plz confirm with our engineer.

(3) Relays’contact status may be changed during transportation or installation due to impact of external force, therefore please reset to the required status.

3.2 Suggestions of relays output

(1) When choosing the relay with hard connection,please avoid the external force on load terminals during or after the installation.

(2) When the relay will be connected with screw or bolts to the relays’ terminals,

plz make sure your connection is fastened and prevent relay from damages or other safety problems due to temp. Rise..

(3) The sampling signal wires of products are limited, please do not pull or torque during installation.

4.Why Choose Us

RCCB RCB Dual Coil 120A Mechanical Magnetic Latching Relay

5.FAQ

Q1: What kind of product and service do you have?

We provide all kinds of electronics including power relay, latching relay, change-over switch, current transformer, shunt, smart sensor, communication & power supply module, transformer etc.

The manufacturer of meter instrument, electrical device, EV charger, medical equipment can find one step solution here. Individual buyer,distributor or (sole/ designated) agents are also welcomed by us.

Q2: Are you are factory or trading company?

We are the manufacturer,designer and sales company. Our own factory was located in Tongxiang city of Zhejiang province.

For our history plz click About us or watch IVY factory video on Youtube.

Q3: Whether the price will change greatly?

To business customers, we mark price can be negotiated here as huge demand.

Usually we will not change the prices unless some force majeure such as trade war, exchange rate change greatly etc.

Q4: Can you offer customized solution, how should I get a quotation?

Yes!We can offer customized products especially when we supply EV accessories and meter accessories. To get a quoation plz kindly offer your basic company info for registration and offer your drawing.

It usually takes 12 hours to 48 hours to filnish the design and drawing (If complicated then plz refer to pracatical situation).

Q5: How do you handle the quality problems?

We are proud of our quality! If any accidents on quality, we have before-sales, in-sales and after-sales service. And every customer will have your own sales expert and technical support.

Send your message to this supplier
Send Now

RCCB RCB Dual Coil 120A Mechanical Magnetic Latching Relay

Ask Latest Price
Watch Video
Brand Name :
IVY
Model Number :
IM1201
Certification :
IEC62055-31,UC3
Place of Origin :
Zhejiang
MOQ :
1
Price :
Negotiated
Contact Supplier
video
RCCB RCB Dual Coil 120A Mechanical Magnetic Latching Relay
RCCB RCB Dual Coil 120A Mechanical Magnetic Latching Relay
RCCB RCB Dual Coil 120A Mechanical Magnetic Latching Relay
RCCB RCB Dual Coil 120A Mechanical Magnetic Latching Relay

IVY METERING CO.,LTD

Active Member
5 Years
shanghai, shanghai
Since 2015
Business Type :
Manufacturer, Trading Company, Seller
Total Annual :
15000000-20000000
Employee Number :
10~1000
Certification Level :
Active Member
Contact Supplier
Submit Requirement