Features
*Compact and portable, easy to use
*With Integrative SpO2 Probe
*Double working modes,monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set
*NIBP and SpO2 can be monitored for a long time
*NIBP and SpO2 data record for large capacity
*With friendly user interface, the user can see list menu and review measure results
*The device can display low power information, alarm information, error information and time information richly
*Parameter alarm function is optional
*Patient information can be flexibly set
*Case management function.PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions
Performance
*NIBP
Measure Method: Oscillometry
Measure Mode: The upper arm measure
Measure range:
ADULT: SYS: 40mmHg~270mmHg
MAP:20mmHg~235mmHg
DIA: 10mmHg~215mmHg
PEDIATRIC: SYS: 40mmHg~200mmHg
MAP: 20mmHg~165mmHg
DIA: 10mmHg~150mmHg
NEONATAL: SYS: 40mmHg~135mmHg
MAP: 20mmHg~110mmHg
DIA: 10mmHg~100mmHg
Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes
Resolution: 1mmHg
Accuracy: ±3mmHg
Increasing pressure mode: force pump increases pressure automatically
Reducing pressure mode: self-motion ladder reducing pressure mode
Alarm parameter: SYS / MAP / DIA
*SPO2
Measure range: 0%~100% (Resolution:1%)
Accuracy: 70-100%, ±2%, below 70% unspecified
Error in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
*Pulse Rate
Measuring range:0bpm~250bpm
Resolution:1bpm
Accuracy: ±2 bpm or ±2% (select larger)
*Display: 2.4" TFT colour LCD
*Power: DC 3V(Two "AA",1.5V Alkali Battery)
*Product safety type:Type BF applied part (Internally powered,defibrillation-proof)
Physics speciality
Dimension: 128mm*69mm*36 mm (No including Packing)
Weight: <350g (Including Batteries)
Accessories
*Cuff for adult
*Integrative SpO2 Probe
*USB data line
*Disk (PC software)
*Pack
*User manual
Software function
*Up to 1000 patient cases can be edited and supervised.
*The time segment of dealing with the patient’s NIBP data is 48 hours.
*Connect the device by USB interface.
*Can upload patient information data collection project and download collection data.
*Can display scoop-shape trend graph,filling-type trend graph, histogram, pie chart, correlation line graph.
*Can edit every piece of data, and add annotation to it.
*Can edit basic information,doctor's advice information, NIBP and SpO2 status instruction, current medicine-taken information, etc.Support print preview,print the report.