New Hand-held Veterinary Pulse Oximeter for Amimals Pets Vet Use with USB Software SpO2 Monitor blood oxygen
Model:AH-60D VET
Introduction
Principle of the CMS60D-VET Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,The Veterinary Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through animal's tongue or ear and so on.The product is suitable for being used in family,pet hospital and etc. (It is recommended to use the device when the animal is still.)
Main Features
. Display Mode 1.8" Color OLED display
· Small in volume,light in weight and convenient in carrying
· Operation of the product is simple ,low power consumption
· Operation menu for the function setting
· SpO2 value display
· Pulse rate value display, bar graph display
· Pulse waveform display
· Screen brightness can be changed
· Pulse rate sound indication
· With review function
· With clock function
· With measured data overruns limits and low-voltage alarm function
· Battery capacity indication
· Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function
· With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
· Real-time data can be transmitted to computers
· Connected with an external oximeter probe
Main perfomance
*Screen Resolution160*128
*SpO2 Measuring Range0%°100%, (the resolution is 1%).
*Accuracy70%°100%2% ,Below 70% unspecified.
*PR Measuring Range30bpm°250bpm, (the resolution is 1bpm)
*Accuracy2bpm or 2% (select larger)
*Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is 4%, pulse rate error is 2 bpm or 2% (select larger).
*Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than 1%.
*Power Consumptionless than 100mA
*Voltage: DC 2.6V~3.6V
*Power Supply: Dry battery(2AA)
*Battery working hour: Theoretical number is 44 hours.
*Safety Type:Interior BatteryBF Type
SPO2
Measurement Range:0 ~ 100%
Resolution:1%
Accuracy: ±2%(70%~100%, Adult/Pediatric, non- motion) ±3%(70~100%, 0% ~ 69% unspecified
Alarm Range:0% ~ 100%
Refreshing Rate:1s
Pulse Rate
Measurement Range:25 ~ 250 bpm
Resolution:1bpm
Accuracy:±3 bpm (non-motion)
Alarm Range:25 ~ 250 bmp
Refreshing Rate:1s
Accessories
Sell in standard
A user manual
A data line
A disk (PC software)
An oximeter probe for animalS5R150_vet
Physical Identity
Dimension:110(L) 60(W) 23(H) mm
Weight:About 180g
By aviation restrictions,bettaries are not included in the package
Qualification
Passed FDA & CE