Menu

Why Can We Always Ensure Excellent Quality

Quality Control

JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

FLOWCHART:

1.screw made of iron(apt to rust) are applied in the regular magnetic switches(Reed) on the market(photo1), while screw made of stainless steel from JSUS to avoid rusty, more stable and better(photo2).
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

2.JSUS Electronics has come out latest magnetic contacts series, whose magnetic switch(Reed switch) used imports of special reed switch OKI-324 ,whose accuracy of magnetic switch & contact life are more than poor reed switches on the market. In production with sleeve insulation, upgrading product quality, eliminating false-signal, while regular magnetic contacts on the market uses poor reed switches, even without insulating tube, easy to appear short-circuit phenomenon between the magnetic switch and housing, finally occurring in false-signal.


JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

3. All magnets from JSUS use "Neodymium iron boron” known as magnetic king in magnetic field, which belongs to the third generation of rare earth permanent magnetic materials, with the advantages of smallest volume, light weight and strong magnet, permanently stable magnetism, while “Ferrimagnet” is usually applied in the regular magnetic contacts on the market which belongs to non-metal magnetism material, easier to lose magnetism.

JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

4. Sometimes “Ferrimagnet” is applied in the regular magnetic contacts on the market, but usually 1 magnet is applied during processing which will result in uneven magnetic force, so appearing false-signal lacking of magnetic force. while 2 magnets are applied from JSUS, to make magnetic force even on the magnetic contacts and to avoid false-signal.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED
5. Each magnet will be tested with a professional testing equipment from JSUS, eligible magnets are allowed to applied in the subsequent production,Magnetic standards are: 3000~3300 Gauss (magnetic strength units),to ensure its quality and stability. While regular magnetic standards in the magnetic contacts on the market are 2000Gauss or so.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

6. During the production line, norm workflow & use of excellent iron pillar, its surface is to polished, smooth body& fine work
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED
7. Eligible iron pillar and “Neodymium iron boron”magnet are assembled into the housing,and then glue filling by filling device, and finally ventilation &drying.. every procedure is strictly executed, clean and orderly.

JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

QC/Technical Support:

Our quality control and technical support department is a combination of highly educated and experienced engineers. A testing center equipped with advanced instruments has also been established in our factory for product quality control.

QC Staff:5 to 9

Procedures/testing Details:

We carry out complete quality control from the purchasing materials to finished products. We choose qualified materials and component to manufacture our items, selective examination by using specialized equipment during process. Our factory test final products according to standard agreed by parties concerned. Our company often sends the engineer to factories for doing factory inspection during production or before delivery.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED
Quality Control Flowchart

  JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

Quality Analytical Flowchart

JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED

Certification

JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: Certificate Of Incorporation
Number: 2052712
Issue Date: 2014-03-13
Scope/Range: security products and accessories
Issued By: Hong Kong Special Administrative Region
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-EMC
Number: YRT201408015C
Issue Date: 2014-08-11
Scope/Range: Magnetic Contacts
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-EMC
Number: YRT201412236C
Issue Date: 2014-12-30
Scope/Range: Smoke Detector
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-LVD
Number: YRT201408016C
Issue Date: 2014-08-11
Scope/Range: Home Alarm System
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: Certificate Of Incorporation
Number: 2052712
Issue Date: 2014-03-13
Scope/Range: security products and accessories
Issued By: Hong Kong Special Administrative Region
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-EMC
Number: YRT201408015C
Issue Date: 2014-08-11
Scope/Range: Magnetic Contacts
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-EMC
Number: YRT201412236C
Issue Date: 2014-12-30
Scope/Range: Smoke Detector
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-LVD
Number: YRT201408016C
Issue Date: 2014-08-11
Scope/Range: Home Alarm System
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-EMC
Number: YRT202301216C
Issue Date: 2023-01-31
Scope/Range: Magnetic Contacts
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CE-EMC
Number: YRT202301217C
Issue Date: 2023-01-31
Scope/Range: Smoke Detector
Issued By: ShenZhen Yarui Testing Co.,Ltd.
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED Certifications
Standard: CPR
Number: NTS1602081S
Issue Date: 2016-02-14
Scope/Range: Smoke Detector
Issued By: NOWD Testing Services Co.,Ltd.
Contact Supplier
Submit Requirement