Air-cooled Precision Cooling For Machine Room With Variable Frequency Fluorine Pump
Product Introduction
Superior Performance | Details |
---|---|
System Characteristics | Three cooling modes that intelligently switch based on outdoor temperature changes. |
Structural Characteristics | Comprises three modules: air-conditioning indoor unit, variable frequency pump energy-saving module, and air-conditioning outdoor unit. |
Working Environment | Working voltage and frequency: 380V ±10% 50 ±3Hz Outdoor ambient temperature range: -45~45°C Indoor temperature range: 18~32°C |
Airflow Range | 6800-26700m³/h |
Cooling Capacity Range | 25-101kW |
Energy Efficiency Ratio | Compressor operation ≥3.0, pump + compressor operation ≥4, pump operation: 7.0~13 |
Sensible Heat Ratio | ≥0.9 |
External Static Pressure | 20-300Pa |
Indoor Temperature Control | 18-32 ±1°C |
Indoor Humidity Control | 40-70% ±5% |
Filter Grade | G4 and above |
Protection Functions | A) System protection: Standard phase sequence protection, under-voltage protection, phase failure protection, point-type water leakage alarm. Optional surge protection, phase sequence error, and belt-type water leakage alarm, etc. B) Component protection: Standard compressor protection, fan alarm, temperature and humidity sensor failure, humidifier protection, heater protection, filter clogging alarm, etc.; Control system with self-diagnosis mode for easy component monitoring and maintenance |
Monitoring Functions | Supports RS-485 communication interface, supports MODBUS-RTU protocol (standard) Supports Ethernet interface, supports MODBUS-TCP, SNMP, HTTP protocols (optional) Supports WEB page access to the unit (optional) |
IP Rating | Indoor unit: IP20; Outdoor unit: IP54 |
Protection Class | Class I |
Fire Resistance Grade | Grade A |
Safety Devices | Optional smoke alarm, fire alarm |
Information Interface | A) Display specifications: Standard 7-inch color touchscreen B) Display content: 1. Real-time operation status of the unit 2. Automatic maintenance reminders, fault diagnosis, component alarm information, etc. 3. Graphical display of temperature and humidity curves, output status of all components, and component operation timing C) Information recording: 1. Operation time of the whole unit and components 2. All operation actions of the unit 3. 500 historical alarm records |
Other Features | Customizable higher efficiency units<br>Multiple return air temperature control methods<br>Variable setpoint control |
The indoor fan of the unit drives air circulation within the room.
During this process, indoor air flows through the air-conditioning evaporator, transferring heat to the refrigerant.
The refrigerant is transported via system piping to the outdoor unit, where the condenser dissipates the heat into the outdoor environment.