1~20kVA Single phase 1/1 Tower UPS
Product Introduction
Power range
1~20kVA
Operation
1P/1P, online double conversion
Applications
Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.
Characteristics
Intelligent battery management..
Wide range of input voltage tolerance.
3-level topology, high performance and efficiency.Adapt to half-wave load.
Online double conversion, full digital control.
Output PF=1,high load adaptability.
Auto fault waveform recording.
Self-aging function to save test energy
Parameters
Model | SS001TB | SS01.5TB | SS001TL | SS002TB | SS002TL | KM003TB | KM003TL |
Rate Power | 1kVA/1kW | 1.5kVA/1.5kW | 1kVA/1kW | 2kVA/2kW | 2kVA/2kW | 3kVA/3kW | 3kVA/3kW |
Cold start | Default output 50/60Hz | Default output 50/60Hz | Default output 50/60Hz | Default output 50/60Hz | Default output 50/60Hz | Default output 50/60Hz | Default output 50/60Hz |
Input voltage range | 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC-176VAC, 50% load@276VAC-300VAC | 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC-176VAC, 50% load@276VAC-300VAC | 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC-176VAC, 50% load@276VAC-300VAC | 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC-176VAC, 50% load@276VAC-300VAC | 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC-176VAC, 50% load@276VAC-300VAC | 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC-176VAC, 50% load@276VAC-300VAC | 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC-176VAC, 50% load@276VAC-300VAC |
Input power factor | ≥0.99 | ≥0.99 | ≥0.99 | ≥0.99 | ≥0.99 | ≥0.99 | ≥0.99 |
Frequency range | 50/60Hz(default), ±3Hz/±10Hz(settable) | 50/60Hz(default), ±3Hz/±10Hz(settable) | 50/60Hz(default), ±3Hz/±10Hz(settable) | 50/60Hz(default), ±3Hz/±10Hz(settable) | 50/60Hz(default), ±3Hz/±10Hz(settable) | 50/60Hz(default), ±3Hz/±10Hz(settable) | 50/60Hz(default), ±3Hz/±10Hz(settable) |
Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Rate output | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) |
Load response | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) |
Recovery time | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) |
Output THDu | ≤2%, Linear load ; 5% non-linear load according to IEC62040-3 | ≤2%, Linear load ; 5% non-linear load according to IEC62040-3 | ≤2%, Linear load ; 5% non-linear load according to IEC62040-3 | ≤2%, Linear load ; 5% non-linear load according to IEC62040-3 | ≤2%, Linear load ; 5% non-linear load according to IEC62040-3 | ≤2%, Linear load ; 5% non-linear load according to IEC62040-3 | ≤2%, Linear load ; 5% non-linear load according to IEC62040-3 |
Transfer time Main to BAT | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Transfer time INV to BYP | 4ms | 4ms | 4ms | 4ms | 4ms | 4ms | 4ms |
Crest factor | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
Efficiency (normal mode) | Max 96% | Max 96% | Max 96% | Max 96% | Max 96% | Max 96% | Max 96% |
Noise (1 meter) | 43dB@<60%load, 47dB@>60%load | 43dB@<60%load, 47dB@>60%load | 43dB@<60%load, 47dB@>60%load | <50dB@<60%load, <55dB@>60%load | <50dB@<60%load, <55dB@>60%load | <50dB@<60%load, <55dB@>60%load | <50dB@<60%load, <55dB@>60%load |
Overload Normal | 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds | 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds | 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds | 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds | 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds | 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds | 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds |
Overload Battery mode | 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds | 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds | 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds | 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds | 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds | 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds | 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds |
Overload Bypass mode | <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds | <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds | <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds | <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds | <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds | <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds | <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds |
Battery Quantity | 3 | 3 | 3 | 6 | 6 | 8 | 8 |
Battery Max charging | 1A | 1A | 1A | 1A | 1A | 1A | 1A |
Battery Rate voltage | 36VDC | 36VDC | 36VDC | 72VDC | 72VDC | 96VDC | 96VDC |
Standard | EPO, RS232 | EPO, RS232 | EPO, RS232 | EPO, RS232 | EPO, RS232 | EPO, RS232 | EPO, RS232 |
Option | SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter | SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter | SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter | SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter | SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter | SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter | SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter |
Dimension ,WDH(mm) | 144×355×226 | 144×355×226 | 144×355×226 | 190×400×328 | 190×400×328 | 144×398×223 | 144×398×223 |
Weight (kg) | 10.5 | 10.5 | 10.5 | 20.5 | 20.5 | 6 | 6 |