-- Power range
10~60kVA
-- Operation
1P/1P, 3P/1P,3P/3P,online double conversion
-- Applications
Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.
-- Characteristics
Full load and full charge: It can charge at full power when the UPS is fully loaded, improving the availability of the battery system;
Peak shaving and valley filling: It supports intelligent switching of charging and discharging periods with low storage and high discharge, saving users' electricity expenses;
Battery without neutral line: The battery has no neutral line design, and the configuration is more friendly to the lithium battery system;
Joint power supply: The mains and batteries can be jointly powered, which is a more flexible and reliable energy management solution
Electricity fee metering: Energy storage UPS intelligently counts daily charge/discharge volume, cumulative charge/discharge volume, charging cost, discharge income, daily net income, cumulative income and other data.
Parameters
Model | KM020/10-ES | KM040/10-ES | KM060/10-ES |
Capacity | 20kVA/20kW | 40kVA/40kW | 60kVA/60kW |
Main Input | |||
Input Wiring | 3-phase + Neutral + PE | ||
Input Voltage | 380/400/415VAC (line voltage) 220/230/240VAC (phase voltage) | ||
Input Frequency | 50/60Hz | ||
Power Factor | >0.99 | ||
Current Distortion | THDi<3% (100% linear load) | ||
Voltage Range | 304~478VAC (line voltage) full load; 304~228VAC (line voltage) load from 100% to 50% linear derating | ||
Frequency Range | 40~70Hz | ||
Battery | |||
Battery Voltage | 240~614.4VDC (no battery neutral required) | ||
Charging Power | Maximum 100% active power | ||
Bypass | |||
Bypass Voltage | 380/400/415VAC (line voltage) 220/230/240VAC (phase voltage) | ||
Voltage Range | Adjustable, default: -20%~+15%; Upper limit: +10%, +15%, +20%, +25%; Lower limit: -10%, -15%, -20%, -30%, -40% | ||
Overload Capacity | 110%, long-term operation 125%<load<150%, not less than 1 minute;110%<load<125%, not less than 5 minutes>150%, 1 second | ||
Output | |||
Rated Output Voltage | 380/400/415VAC (line voltage); 220/230/240VAC (phase voltage) | ||
Rated Frequency | 50/60Hz | ||
Output Power Factor | 1 | ||
Voltage Accuracy | ±1.0% | ||
Output Dynamic Response | <5% (20%~80%~20% step load) | ||
Dynamic Recovery Time | <20ms (0%~100%~0% step load) | ||
Output Total Harmonic Distortion (THDu) | <1% (linear load), <5% (non-linear load) | ||
Inverter Overload | 110%, 1 hour then bypass; 125%, 10 minutes then bypass; 150%, 1 minute then bypass; >150%, 200ms then bypass | ||
Frequency Accuracy | 0.10% | ||
Tracking Range | Adjustable, ±0.5Hz~±5Hz, default ±3Hz | ||
Tracking Speed | Adjustable, 0.5Hz/S~3Hz/S, default 0.5Hz/S | ||
Crest Factor | 3:01 | ||
Three-Phase Balance Accuracy | 120° ±0.5° | ||
System | |||
System Efficiency | Main mode ≥96.5%; Battery mode ≥96.5% | ||
Display | LCD + LED + 7-inch color touchscreen | ||
Safety Standards | IEC62040-1,IEC60950-1 | ||
EMC | IEC62040-2; IEC61000-4-2 (ESD); IEC61000-4-3 (RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | ||
System Protection Level | IP20 | ||
Standard Interfaces | USB, RS232, RS485, dry contact card, battery cold start | ||
Optional Accessories | SNMP card, extended dry contact card, parallel components, LBS, APP/WiFi/bluetooth | ||
Operating Environment | 0~40°C (operating temperature); -25°C~70°C (storage temperature); 0~95% (non-condensing) | ||
Noise (dB) @1m | 65dB @100% load, 62dB @45% load | ||
Dimensions | |||
Cabinet (W×D×H) mm | 442×710×307 (7U) | 442×710×575 (10U) | 442×710×882 (20U) |
Module (W×D×H) mm | 400×495×86 (2U) | ||
Note: Specifications are subject to change without notice. Please refer to the actual product for details. |