6kVA 10kV 1/1 Single Phase Rack Mounted Ups Power Supply
With internal battery
With external battery
Power range
6kVA 10kVA 1P/1P online double conversion
Applications
Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.
Characteristics
Intelligent battery management.
3-level topology, high performance andefficiency.
Online double conversion, full digital control.
Output PF=1,high load adaptability.
Wide range of input voltage tolerance.
Adapt to half-wave load.
Auto fault waveform recording.
Self-aging function to save test energy.
10kW in 2u, high power density.
Parameters
Model | SS006BR | SS006LR | SS010BR | SS010LR |
---|---|---|---|---|
Rate Power | 6kVA/6kW | 6kVA/6kW | 10kVA/10kW | 10kVA/10kW |
Cold start | Default output 50/60Hz | Default output 50/60Hz | Default output 50/60Hz | Default output 50/60Hz |
Input voltage range | 110~288VAC; 100% load@176VAC; 90% load@154VAC; 75% load@132VAC; 50% load@110VAC | 110~288VAC; 100% load@176VAC; 90% load@154VAC; 75% load@132VAC; 50% load@110VAC | 110~288VAC; 100% load@176VAC; 90% load@154VAC; 75% load@132VAC; 50% load@110VAC | 110~288VAC; 100% load@176VAC; 90% load@154VAC; 75% load@132VAC; 50% load@110VAC |
Input power factor | ≥0.99 | ≥0.99 | ≥0.99 | ≥0.99 |
Frequency range | 40-70Hz | 40-70Hz | 40-70Hz | 40-70Hz |
Output power factor | 1.0 | 1.0 | 1.0 | 1.0 |
Rate voltage | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) | 220/230/240VAC, 200/208VAC(PF=0.9) |
Load response | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) | ≤5% (0% - 100% -0%) |
Recovery time | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) | ≤40ms (0% - 100% -0%) |
THDu | ≤1%, linear load; ≤5%, non-linear load according to IEC62040-3 | ≤1%, linear load; ≤5%, non-linear load according to IEC62040-3 | ≤1%, linear load; ≤5%, non-linear load according to IEC62040-3 | ≤1%, linear load; ≤5%, non-linear load according to IEC62040-3 |
Transfer time-Main to Battery | 0ms | 0ms | 0ms | 0ms |
Transfer time-INV to BYP | 0ms | 0ms | 0ms | 0ms |
Crest factor | 3:1 | 3:1 | 3:1 | 3:1 |
Battery type | 12VDC/7Ah | External battery | 12VDC/9Ah | External battery |
Battery Number | 16PCS | 16-24 PCS settable | 16PCS | 16-24 PCS settable |
Battery voltage | 192VDC (default), settable | 192VDC (default), settable | 192VDC (default), settable | 192VDC (default), settable |
Max charging | 1A | 5A | 1A | 5A |
Efficiency –normal charging mode | Max 95% | Max 95% | Max 95% | Max 95% |
Noise (1 meter) | <58dB | <58dB | <58dB | <58dB |
Overload Normal mode | 105%~110%: 10mins, 111%~125%: 1 min, 126%~150%: 30 seconds | 105%~110%: 10mins, 111%~125%: 1 min, 126%~150%: 30 seconds | 105%~110%: 10mins, 111%~125%: 1 min, 126%~150%: 30 seconds | 105%~110%: 10mins, 111%~125%: 1 min, 126%~150%: 30 seconds |
Overload ECO mode | <125%: long time, 126%~130%:5mins, 131%~150%:1min, >150%:200ms | <125%: long time, 126%~130%:5mins, 131%~150%:1min, >150%:200ms | <125%: long time, 126%~130%:5mins, 131%~150%:1min, >150%:200ms | <125%: long time, 126%~130%:5mins, 131%~150%:1min, >150%:200ms |
Communication Option | RS232, EPO, RS485 | AS400, USB, SNMP card, 12A charger, Parallel kit, Air filter | RS232, EPO, RS485 | AS400, USB, SNMP card, 12A charger, Parallel kit, Air filter |
Dimension WDH(mm) | 440*660*172 | 440*580*86 | 440*660*172 | 440*580*86 |
Weight(kg) | 62.5 | 16 | 63 | 18 |