MEASTEK MDP5150B 120MHz 1500Vpk Floating Measurement Isolation High Voltage Differential Active Oscilloscope Probes
Key Features:
【120MHz bandwidth ×1500V high voltage】
120MHz bandwidth + 2.9ns rise time, accurately capture high-frequency signals
50X/500X dual attenuation ratio, supports wide range measurement from ±150Vpk to ±1500Vpk
【Fully compatible with BNC interface】
Adapt to all brands of oscilloscopes such as Tektronix/Keysight/Rigol
1MΩ/50Ω impedance automatic recognition, 50Ω mode attenuation ratio doubled to 1000X
【Triple safety protection】
CE/UL certification, overload protection threshold reaches 1500Vpk (red light alarm)
IP54 waterproof and dustproof, 5MΩ high impedance + 2pF low capacitance design
【Intelligent functions improve efficiency】
Automatically save waveform data, no loss when power off
USB 5V power supply, plug and play without additional power supply
【Industrial application scenarios】
Switching power supply / inverter / Inverter high-voltage side test
New energy BMS battery pack differential voltage monitoring
Motor drive module IGBT switching loss analysis
Specifications
Model | MDP5150B |
Bandwidth (-3dB) | 120 MHz |
Rise time (ns) | ≤2.9 |
Accuracy | 1% |
Attenuation ratio | 50X/500X |
Maximum differential measurement voltage (DC+Peak AC) | 50X ±150Vpk |
500X ±1500Vpk | |
Effective value | 50X ±106Vrms |
500X ±1060Vrms | |
Maximum input voltage to ground (Vrms) | 600V CATII 1000V CATI |
Common mode voltage(DC+Peak AC) | ±1500Vpk |
Input Impedance | Single-ended to ground 2.5MΩ |
Two input terminals 5MΩ | |
Input Capacitance | Single-ended to ground <4pF |
Two input ends <2pF | |
CMRR | DC >80dB |
100kHz>60dB | |
1MHz>50dB | |
Noise (Vrms) | 50X <50mV |
500X <300mV | |
Delay time | Host: about 9ns |
BNC cable 1m: about 5ns | |
Overload indicator voltage threshold | 50X >150Vpk |
500X >1500Vpk | |
Overload indicator light (red light) | Yes |
Auto-save function | Yes |
Terminal load requirement | ≥100kΩ |
power supply | USB 5V/1A adapter |
Probe Standard Accessories
Name | Object | Parameters |
Alligator Clips | ![]() | CATIII 1000V CATIV 600V |
Piston probe clamp | ![]() | CATIII 1000V |
Test Hook | ![]() | CATII 1000V |
Input extension cord | ![]() | CATIII 1000V |
BNC output cable | ![]() | BNC male to male output cable (length 1 meter) |
Power output line | ![]() | Length 1 meter |
Power adapter | USB 5V/1A |
WARNING: To avoid the risk of electric shock or fire, do not use the MDP5700A/ MDP5700B/ MDP5700C probes or hook tip accessories on CAT III or CAT IV circuits. To avoid the risk of electric shock or fire, do not use the MDP5700A/ MDP5700B/ MDP5700C test probes or hook tip accessories on circuits above 7000V when using the MDP5070A/ MDP5070B/ MDP5070C probes.
Use only accessories rated for the application. Substituting other accessories may create a risk of electric shock or burns. Keep the probe body and accessories clean to reduce the risk of electric shock from conductive surfaces.
Packing List
Name | Quantity |
High-voltage differential probe | 1 piece |
Alligator Clips | 1 pair |
Piston probe clamp | 1 pair |
Test hook | 1 pair |
Input extension cable | 1 pair |
BNC output cable | 1 piece |
Power output cable | 1 piece |
Power adapter | 1 piece |
Test report | 1 serving |
Warranty card | 1 piece |
Probe box | 1 piece |