UHCT0060A Wideband Current Probe 100mV/A Sensitivity For Capacitor Discharge Analysis | Industrial Grade Temperature Resistant Design
1.Balanced sensitivity and range: 100mV/A sensitivity, peak current 0.06kA, taking into account both accuracy and medium current scenarios.
2.High frequency response 50MHz: Quickly capture transient current, such as capacitor discharge waveform analysis.
3.Low attenuation characteristics 78%/ms: Reduce signal distortion and truly restore current waveform.
4.Compact and lightweight design: The total weight is only 180g, suitable for mobile detection needs.
5.Standard BNC interface: Compatible with mainstream oscilloscopes, plug and play.
6.High temperature resistant probe ring: The operating temperature range is 0℃-100℃, suitable for harsh industrial environments.
Technical Parameters
Model | UHCT0060A |
Sensitivity (mV/A) | 100 |
Peak current (KA) | 0.06 |
Maximum noise (mV Vp-p) | 18 |
Attenuation characteristics (%/ms) | 78 |
Low frequency bandwidth -3dB (Hz) | 100 |
Peak di/dt (A/ns) | 4.0 |
High frequency bandwidth -3dB (MHz) | 50 |
Note: If you need a larger range, please consult the manufacturer. It can be customized according to your requirements.
Other Technical Parameters
Accuracy | 2% | |
Insulation withstand voltage value | 2KV | |
Terminal load | ≥100kΩ | |
Power supply method | USB 5V (standard adapter) | |
Ring circumference | 100mm (customizable) | |
Coil lead length | 1.0m (customizable) | |
Operating temperature range | Integrator | 0℃ - 50℃ |
Probe ring | 0℃ - 100℃ | |
Storage temperature range | -40℃~80℃ | |
Front end dimensions | About 110(L)*45(W)*30(H)mm | |
Probe weight | Integrator | About125g |
Total weight | About180g |
Product Description
1) Input interface: probe ring input interface.
2) Output interface: integrator output interface.
3) USB 5V power supply interface: standard USB (type B) interface, USB power supply cable as standard.
Probe induction ring body diameter: 3.5mm
Coil circumference: 100mm
Care And Maintenance
*The current transmitter can only be guaranteed to operate safely and trouble-free if it is properly transported, stored, installed, and carefully operated and maintained.
*Keep the probe clean and dry, and wipe it with a soft dry cloth.
*When transporting the probe, put it in the standard packaging to prevent shock.
*Do not force the flexible probe ring and connecting wire to avoid damage due to excessive twisting, bending or knotting.
Packing List
Integrator | 1 piece |
Flexible coil | 1 piece |
USB output adapter (5V/1A) | 1 piece |
USB power cable | 1 piece |
BNC output cable | 1 piece |
Electronic manual | 1 serving |
Notes
1. To ensure measurement accuracy, the measured wire should pass through the center of the probe ring during measurement.
2. The error is greatest at the junction of the induction rings, and the measured wire should try to avoid this area.
3. Make sure the probe ring is inserted in place (to the bottom) during measurement, otherwise it will affect the measurement accuracy.
4. When measuring the measured signal, if there is a strong magnetic field interference source nearby (such as a magnetic field radiation source composed of multiple coils), it should be kept as far away as possible, otherwise it will cause measurement errors.