MEASTEK UHCT012KA 12kA Lightning Current Probe | 2%/ms Low Attenuation | Extreme Environment Adaptation | Shockproof And Moisture-proof Packaging | Dedicated For Power Systems | Customized Sensitivity
1. Ultra-large capacity design: peak current 12kA, optimized for short-circuit/lightning current detection in power systems.
2. High-frequency bandwidth 50MHz: supports microsecond transient waveform analysis, such as lightning impulse current.
3. Low attenuation characteristics 2.0%/ms: minimize signal distortion and ensure data authenticity.
4. High temperature and corrosion resistance: the probe ring material adapts to extreme environments and extends service life.
5. Flexible customization service: supports coil circumference and sensitivity customization to meet special scene requirements.
6. Standard protective packaging: shockproof and moisture-proof design to ensure transportation and storage safety.
Technical Parameters
Model | UHCT012KA |
Sensitivity (mV/A) | 0.5 |
Peak current (KA) | 12.0 |
Maximum noise (mV Vp-p) | 10 |
Attenuation characteristics (%/ms) | 2.0 |
Low frequency bandwidth -3dB (Hz) | 1.3 |
Peak di/dt (A/ns) | 160 |
High frequency bandwidth -3dB (MHz) | 50 |
Note: If you need a larger range, please consult the manufacturer. It can be customized according to your requirements.
Other Technical Parameters
Accuracy | 2% | |
Insulation withstand voltage value | 2KV | |
Terminal load | ≥100kΩ | |
Power supply method | USB 5V (standard adapter) | |
Ring circumference | 100mm (customizable) | |
Coil lead length | 1.0m (customizable) | |
Operating temperature range | Integrator | 0℃ - 50℃ |
Probe ring | 0℃ - 100℃ | |
Storage temperature range | -40℃~80℃ | |
Front end dimensions | About 110(L)*45(W)*30(H)mm | |
Probe weight | Integrator | About125g |
Total weight | About180g |
Product Description
1) Input interface: probe ring input interface.
2) Output interface: integrator output interface.
3) USB 5V power supply interface: standard USB (type B) interface, USB power supply cable as standard.
Probe induction ring body diameter: 3.5mm
Coil circumference: 100mm
Care And Maintenance
*The current transmitter can only be guaranteed to operate safely and trouble-free if it is properly transported, stored, installed, and carefully operated and maintained.
*Keep the probe clean and dry, and wipe it with a soft dry cloth.
*When transporting the probe, put it in the standard packaging to prevent shock.
*Do not force the flexible probe ring and connecting wire to avoid damage due to excessive twisting, bending or knotting.
Packing List
Integrator | 1 piece |
Flexible coil | 1 piece |
USB output adapter (5V/1A) | 1 piece |
USB power cable | 1 piece |
BNC output cable | 1 piece |
Electronic manual | 1 serving |
Notes
1. To ensure measurement accuracy, the measured wire should pass through the center of the probe ring during measurement.
2. The error is greatest at the junction of the induction rings, and the measured wire should try to avoid this area.
3. Make sure the probe ring is inserted in place (to the bottom) during measurement, otherwise it will affect the measurement accuracy.
4. When measuring the measured signal, if there is a strong magnetic field interference source nearby (such as a magnetic field radiation source composed of multiple coils), it should be kept as far away as possible, otherwise it will cause measurement errors.