Model | WD-1001M-DIN(T/V) | WD-1001M-DIN(D) | |
Interface | 1*LAN 10/100/1000Base-TX self adaption RJ45,1*AC power interface MDI/MDX support | 1*LAN 10/100/1000Base-TX self adaption RJ45,1*DC power interface MDI/MDX support | |
LED display light | Ethernet, PLC link ,power | ||
Transfer band | 25,50 and 100MHz and MIMO (based on G.9963) | ||
Protocol(PHY) | IEEE802.3,IEEE802.3x, IEEE802.3u G.Hn | ||
Security | 128-AES | ||
Transfer rate(PHY) | 800Mbps | ||
Modulation | OFDM | ||
Effective transfer rate | TCP/IP 400Mbps | ||
Manageability | Remote Firmware update,support TR-069(optional) | ||
802.1D Ethernet Bridge | |||
802.1Q VLAN | |||
Quality of Service(QoS) | |||
IGMO(IPv4)Snooping&MLD(IPv6)Snooping | |||
Working voltage | AC 90V-520V |
18-75VDC 100V-700VDC
|
|
Operating temperature | -40℃-80℃ | ||
Size | 120*89*44 (mm)(L×W×H)(not include installation hook) | ||
Weight | 0.35kg | 0.30kg | |
Operating environment | Operating humidity:10%-85% (no condense) | ||
Storage humidity: 5%-90%(no condense) | |||
Certification | FCC,CE class B,WEEE,RoHS |
Features
Packet loss:≤0.1%(100M,load 70%)
Support 7*24 hours all weather operation
hardware watch dog function
PING≤2MS
The quantity of the group ≤16pcs
Immunity of ESD
The testing voltage which the device should be beared: ±6kV direct Discharge, ±8kV air discharge. Discharge number in Each sensitive testing point: Plus-n-Minus 10 times each, Every time the discharge interval is 1 s, according to B/T 17626.2-2006.
Immunity of electrical fast transient impulse group(Common mode)
The testing voltage which the device should be beared: between the power supply voltage port and ground: ±2.0kV, between signal circuit and ground: ±1.0kV, repetition frequency: 5KHz, test duration: 1 min/ time, testing times: Plus-n-Minus 5 times each. According to GB/T 17626.4-2008.
Anti interference of surge impact
The testing voltage which the device should be beared: ±2kV, the interval of continuous impulses: 1min/time. Test number: Plus-n-Minus 5 times each. According to GB/T 17626.5-2008.(protection: all models protection and varistor series of discharge tube type)
Anti- vibration
Meet the demand of MX3 in TB1433(0-200Hz,2g acceleration, maximum amplitude 7mm), interface with no loose, device with no Sealing off and drop in the test.