Environmental Stability Chambers for Pharmaceutical Stability Testing FDA/ICH
Features
Independent over-temperature protection with automatic defrosting function and long-term continuous operation
The door is equipped with a key lock and has a large observation window
Interior chamber has an internal storage tank
Imported refrigeration compressor unit to ensure stable and reliable testing
Working chamber uses mirror surface SUS304A stainless steel, which is acid-resistant, corrosion resistant and easy to clean
Temperature/humidity deviation alarm (near sound and light alarm, remote door room alarm, SMS alarm); One key release function setting for lofting or withdrawing pharmaceutical specimen
Condensing wastewater can be recycled which can save energy and extend the frequency of water use
Using imported France polymer temperature and humidity sensors for precise humidity measuring, no maintenance
What is a Pharmaceutical Stability Test Chamber ?
Pharmaceutical Stability Chambers from ATMARS are perfectly designed for the high requirements of stability studies, steady state, accelerated aging, shelf life testing, expiration date testing and climatic tests. With Stability Chambers specifically developed to meet FDA/ICH stability requirements generating exceptional control and uniformity of both temperature and humidity.
Stability Test Chambers used by pharmaceutical and drug companies in product research & development need the most reliable, powerful design and available construction.
ATMARS Pharmaceutical Stability Chambers standard models workspace volumes include: 216L, 468L, 969L, 1980L, 2880L to walk-in /drive-in sizes. And interior dimensions can be customized according to specimen sizes and your testing requirements.
Performance
Temperature range: +15℃ to +65℃
Humidity range: 15%RH to 95%RH
Technical Specifications of AS Series Pharmaceutical Stability Chambers Performance is based on ambient temperature +20℃ or circulating water temperature +25℃, empty load no specimen. | ||||||
Model | AS- | |||||
220 | 500 | 1000 | 2000 | 3000 | ||
Performance | Temperature Range | +15℃~+65℃ | ||||
Humidity Range | 15%RH~95%RH | |||||
Temperature Fluctuation | ±0.5℃ | |||||
Temperature Deviation | ±1.0℃ | |||||
Humidity Deviation | ±3.0%RH | |||||
Workspace Volume | 216L | 468L | 969L | 1980L | 2880L | |
Workspace Dimensions (WxDxH)mm | 600 | 600 | 850 | 1100 | 1200 | |
600 | 600 | 950 | 1200 | 1200 | ||
600 | 1300 | 1200 | 1500 | 2000 | ||
Exterior Dimensions (WxDxH)mm | 760 | 760 | 1010 | 1260 | 1740 | |
1160 | 1160 | 1510 | 1760 | 1530 | ||
1200 | 1900 | 1800 | 2100 | 2300 | ||
Material | Interior | #SUS304 Stainless Steel | ||||
Exterior | Cold-rolled steel with powder coated surface | |||||
Core Parts | Controller | Touch screen microcomputer controller | ||||
Humidity Sensor | Electronic humidity sensor | |||||
Temperature Sensor | PT100 temperature sensor | |||||
Compressor | Low-power heat-resistant refrigeration compressor | |||||
Refrigerant | Zero ozone depletion potential (ODP) refrigerant | |||||
Data Recorder | Micro printer paper record; paperless recording, built-in SD card export; real-time computer data recording; export via RS485 interface. | |||||
Centralized Control | One computer can connect multiple devices in the same series at the same time, up to 30 instruments. | |||||
Remote Monitor | Using Internet and Sims software to realize remote commission and monitor | |||||
Timing | Time accumulator | |||||
Safety | Independent workspace over temperature protection; humidification system water cut; refrigeration compressor unit overload protection; mobile phone SMS alarm system. | |||||
Standard configuration | 1 x multi-pane viewing window; 1 x cable access port; 1 x internal light; 4 x casters; 1 x power cable; 1 x inner glass door (except model AS-3000) | |||||
Quantity of Shelves | 3 | 6 | 5 | 7 | 9 | |
Compressor Unit | 2 Sets | 2 Sets | 3 Sets | 4 Sets | 4 Sets | |
Installation Power | 1800W | 2300W | 2300W | 3500W | 3500W | |
Power Supply | AC 220V 50Hz | |||||
▲Custom options are available. |
Special 3Q certification technical services: IQ (installation confirmation), OQ (operation confirmation) and PQ (performance confirmation)