Programmable Walk In Environmental Test Chamber Stability 3 Phase 380V 50Hz
Available in FOUR standard temperature ranges:
Type A: -20℃ to +150℃
Type B: -40℃ to +150℃
Type C: -60℃ to +150℃
Type D: -70℃ to +150℃
Standard humidity range: 20%RH to 98%RH (Optioal lower humidity is available.)
What is a Walk-In Chamber?
Walk-In Chambers from ATMARS serves as an ideal test site for large components, assemblies, and finished products. We manufacture both Panel (modilar) Walk-In Chambers and Solid (welded) Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber. A Panel Walk-In Chamber is made from lightweight insulated panels for fast and easy installation.
ATW/AHW Configurations:
ATW Series - Temperature only
AHW Series - Temperature and humidity capability
Technical Specifications of AHW-6 SERIES Walk-in Environmental Chambers Performance is based on ambient temperature +20 ℃ or circulating water temperature +25 ℃, empty load no specimen. | |||||
Model | AHW-6A | AHW-6B | AHW-6C | AHW-6D | |
T&H Adjustment Mode | Smart balanced temperature (humidity) control - BT(H)C | ||||
Performance | Temperature Range | -20℃ to +150℃ | -40℃ to +150℃ | -60℃ to +150℃ | -70℃ to +150℃ |
Temperature Fluctuation | ±0.5℃ | ||||
Temperature Uniformity | ±2.0℃ | ||||
Temperature Devitaion | ±2.0℃ | ||||
Heat-up Rate (Average) | From -20℃ to +150℃ 3℃/min. | From -40℃ to +150℃ 3℃/min. | From -60℃ to +150℃ 3℃/min. | From -70℃ to +150℃ 3℃/min. | |
Cool-down Rate (Average) | From +20℃ to -20℃ 1℃/min. | From +20℃ to -40℃ 1℃/min. | From +20℃ to -60℃ 1℃/min. | From +20℃ to -70℃ 1℃/min. | |
Humidity Range | 20%RH to 98%RH | ||||
Humidity Fluctuation | ±2.5%RH | ||||
Humidity Deviation | ±3.0%RH when Humidity>75%RH; ±5.0%RH when Humidity≤75%RH. | ||||
Workspace Volume | 5.797m³ | ||||
Workspace Dimensions | W1550xD2200xH1700mm | ||||
Exterior Dimensions | W1750xD3600xH2600mm | ||||
Material | Interior | #SUS304 Stainless Steel | |||
Seal | Imported silicone seal | ||||
Insulation | Expanded foam & fiberglass | ||||
Exterior | Cold-rolled steel with powder coated surface | ||||
System | Heating | Nichrome Resistance Wire Heater | |||
Refrigeration | Mechannical Refrigeration System | ||||
Humidification | Stainless Steel Humidifier (Vapor generator system) | ||||
Controller | Programmable Touch-screen Controller | ||||
Noise Level | ≤70dB (A-weighted sound pressure level measured at a distance of 1.0 meter) | ||||
Allowable Ambient Conditions | Temperature: +5℃ to +35℃; Relative humidity: ≤85%RH (No condensation); Air pressure: 86kPa to 106kPa. | ||||
Power Supply | AC 380 (1±10%)V (50±0.5)Hz 3 Phase 4 Wire plus Earth Wire | ||||
▲Custom options are available. |
Test Standards Conformance
GB/T 10586-2006 Specifications for damp heat chambers
GB/T 10592-2008 Specification for low/high temperature test chambers
GB/T 2423.1-2008 Environmental testing - Part 2: Test methods - Tests A: Cold
GB/T 2423.2-2008 Environmental testing - Part 2: Test methods - Tests B: Dry heat
GB/T 2423.3-2016 Environmental testing—Part 2: Testing method—Test Cab: Damp heat,steady state
GB/T 2423.4-2008 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12h+12h cycle)
GB/T 2423.22-2012 Environmental testing - Part 2: Tests methods - Test N: Change of temperature
GJB 150.3A-2009 Laboratory environmental test methods for military material - Part3: High temperature test
GJB 150.4A-2009 Laboratory environmental test methods for military material - Part4: Low temperature test
GJB 150.9A-2009 Laboratory environmental test methods for military material - Part9: Damp heat test
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-78:2012 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state