ST116 Coarse Fiber tester
ST116 Coarse Fiber tester tests raw fiber content according to acid and alkali boiling method.It adopts accurate concentration acid and alkali to boil samples in particular condition, then remove soluble substances by Diethyl oxide, deduct the amount of minerals by high temperature burning.
Hot Sale Crude Fiber Tester /Coarse Fiber Tester
Coarse Fiber Analyzer or Raw Fiber Tester
Raw Fiber Analyzer Lab Coarse Fiber Tester
Coarse Fiber Analyzer or Raw Fiber Analyzer
Technical parameter:
Measuring object:raw fiber content in various kinds of grain, feed, food and other agriculture and sideline products
Measuring sample quantity:6/times
Reproducibility error:
Raw fiber level < 10% absolute value erroe≤0.4%
Raw fiber level >10% absolute value error≤4%
Measuring time:about 100min (including acid 40min, alkali 40min, filter and wash 20 min)
Power:AC220V/50HZ
Size:540×450×670mm
Weight:28kg
Measuring object | Raw / Coarse fiber content in various kinds of grain, feed, food and other agriculture and sideline products |
Measuring sample quantity | 6/times |
Reproducibility error | Raw fiber level < 10% absolute value error≤0.4% Raw fiber level >10% absolute value error≤4% |
Measuring time | It takes about 90 minutes on the instrument (including 30 minutes for acid, 30 minutes for alkali, and about 30 minutes for filtration and washing); |
Power: | 3.3KVA |
Size:540×450×670mm Weight:28kg |
Packing list
S/N | Name | Quantity | Unit | Remarks |
1 | Host | 1 | set | |
2 | Fiber crucible | 6 | piece | |
3 | Glass Flask | 3 | piece | |
4 | Power cord | 1 | piece | |
5 | Fuse tube | 1 | piece | 10A in the safety seat |
6 | instructions | 1 | copy | |
7 | Certificate warranty card | 1 | copy |
Technical parameter:
Measuring object:raw fiber content in various kinds of grain, feed, food and other agriculture and sideline products
Measuring sample quantity:6/times
Reproducibility error:
Raw fiber level < 10% absolute value erroe≤0.4%
Raw fiber level >10% absolute value error≤4%
Measuring time:about 100min (including acid 40min, alkali 40min, filter and wash 20 min)
Power:AC220V/50HZ
Size:540×450×670mm
Weight:28kg
Measuring object | Raw / Coarse fiber content in various kinds of grain, feed, food and other agriculture and sideline products |
Measuring sample quantity | 6/times |
Reproducibility error | Raw fiber level < 10% absolute value error≤0.4% Raw fiber level >10% absolute value error≤4% |
Measuring time | It takes about 90 minutes on the instrument (including 30 minutes for acid, 30 minutes for alkali, and about 30 minutes for filtration and washing); |
Power: | 3.3KVA |
Size:540×450×670mm Weight:28kg |