SARS-CoV-2 Antigen Saliva Rapid Test Kit (Immunochromatography)
Intend Use
- Qualitative detection of SARS-CoV-2 antigen in human saliva sample
- Positive result of the antigen test can be used for early triage and rapid management of suspected populations
- Negative results do not rule out SARS-CoV-2 infection and should not be used as the sole basis for treatment or patient management decisions.
- Nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.
Product Details
Item | Value |
Brand | Labnovation |
Model Number | LX-401603 |
Type | 20 Test |
Warranty | 18 Months |
Quality Certification | CE, MSDS |
Safty Standard | ISO13485 |
Sample Type | Saliva |
Sample volume | 3 Full drops |
Test Speed | Within 15 minutes |
specificity | 99.00% |
sensitivity | 94.29% |
Product Feature
- Fast: Result easy to read within 15 minutes
- Simple: One step operation process
- Reliable: Individual package buffer, safety and reliability
- Accurate: High accuracy, specificity and sensitivity


Main Components
- 20 Test Cassettes
- 20 Saliva Collectors With Collection Tubes
- 20 Sample Extraction Buffer
- 1 Tube stand
- 1 Package Insert

Use Step
- Open the cap of the collection tube and istall saliva collector.
- Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
- Screw the sample extraction buffer carefully.

- Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
- Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
- Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

Result Interpretation
POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.
INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

Virus Sources
Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
B.1.1.33.etc | C.1.1.etc. | |