Rapid Test Kit SARS-CoV-2 Neutralizing Antibody Rapid Test Kit Professional Test Excellent Proformance
Intended Use
The SARS-COV-2 Neutralizing Antibody Rapid Test Kit is intended use as an aid in identifying individuals with an adaptive immune response to SARS-COV-2, indicating recent or prior infection or assisting in evaluating the effectiveness of the vaccine clinical trials and mass vaccination. Results are for the detection of total neutralizing antibodies to SARS-COV-2. Antibodies to SARS-COV-2 are generally detectable in blood several days after initial infection.
Specifications
Test Item | Neutralizing Antibody Test Kit |
Number | LX-401701 |
Sample Volume | Whole blood , Serum, Plasma |
Package | 20 Tests/Kit |
Specificity | 98.00% |
Sensitivity | 97.67% |
Accuracy | >95% |
nspection Method | Immunochromatography |
Shelf Life | 18 Months |
Type | IVD Antibody Rapid Test |
Humidity | 35%-60% |

Main Components
- 20 Test cassettes
- 20 Disposable pipettes
- 20 Sterile Safety Lancets
- 1 Specimen Buffer
- 1 Colorimetric chart
- 1 Instruction Manual
Product Feature
- High Accuracy, Specificity and Sensitivity
- Easy to operate and requires without additional equipments
- Fast Recation, read the result within 15 minutes
- Room Temperature Storage

Advantage
- Accurate: the product has a high accurate serology test for Neutralizing Antibodies detection
- Easy to learn and use
- Less sample volume. Support sample type of fingertip blood
- Read test result visualli, no need of test equipment
Use Step
- Place the lanceton the test site.
- Push down the lancet.
- Collect the bloodby transfer pipette.

- Add one drop of blood into the sample well.
- Add 1-2 drops (30-60µL) of sample buffer into the sample well innediately.
- Wait 15 minutes then read the result.

Interpretation of results
- POSITIVE: The T line and C line are both displayed within the reaction window, indicates the neutralizing antibodies to SARS-COV-2 are detected. The result is positive.
- NEGATIVE:The C line is displayed within the reaction window only, indicates absence of neutralizing antibody to SARS-COV-2.The result is negative..
- INVALID:1. If the control (C) line is not displayed in 15 min, regardless of whether T line is present, the test result is invalid. It is recommended that the specimen should be re-tested.
The test result is invalid after 20 min.

Applicaton
- Evaluation of Vaccination
- Diagnosis of Infection
- Assessment of Convalescent Plasama Therapy
- Epidemiology Research
FAQ
We have the MOQ limit,which is 10000 pieces.
After order confirmed,we will arrange your order immediately,and offer you an
estimated delivery date.
Business to business account.
We choose Air cargo or Ocean cargo.
- Trade Company or Manufacturer:
Manufacturer