Rapid Antibody Rapid Test Kit Neutralizing Antibody Detection Rapid Test Kit High Quality Test Kit
Intended Use
The SARS-COV-2 Neutralizing Antibody Rapid Test Kit is the semi-quantitative determination of neutralizing antibodies, the test result as an aid in identifying individuals with an adaptive immune response to SARS-COV-2, indicating recent or prior infection or assisting in evaluating the effectiveness of the vaccine clinical trials and mass vaccination.
Specifications
Test Item | Neutralizing Antibody Test Kit |
Number | LX-401701 |
Application | For Professional Testing Use |
Specificity | 98.00% |
Sensitivity | 97.67% |
Total Acuracy | More than 95.00% |
Sample Volume | Whole blood 20µL, Serum/Plasma 10µL |
Package | 20 Tests/Kit |
nspection Method | Immunochromatography |
Shelf Life | 18 Months |
Type | IVD Antibody Rapid Test |
Humidity | 35%-60% |
Application | For Professional Testing Use |

Main Components
- 20 Test cassettes
- 20 Disposable pipettes
- 20 Sterile Safety Lancets
- 1 Sample Buffer
- 1 Colorimetric chart
- 1 Instruction for use
Product Feature
- Fast Test, get antigen test result within 10-15 minutes.
- High sensitivity and specificity
- Easy to operate, no need equipment, convenient and fast
- Require little Specimens

Notic
- Sample should be human serum, plasma and whole blood only, other body fluid samples are not tested and may cause incorrect or inaccurate results.
- All reagents have to be brought to room temperature (18 to 25 °C) before performing the test.
Use Step
- Place the lanceton the test site.
- Push down the lancet.
- Collect the bloodby transfer pipette.

- Add one drop of blood into the sample well.
- Add 1-2 drops (30-60µL) of sample buffer into the sample well innediately.
- Wait 15 minutes then read the result.

Interpretation of results
- POSITIVE: The T line and C line are both displayed within the reaction window, indicates the neutralizing antibodies to SARS-COV-2 are detected. The result is positive.
- NEGATIVE:The C line is displayed within the reaction window only, indicates absence of neutralizing antibody to SARS-COV-2.The result is negative..
- INVALID:1. If the control (C) line is not displayed in 15 min, regardless of whether T line is present, the test result is invalid. It is recommended that the specimen should be re-tested.
The test result is invalid after 20 min.

LIMITATIONS
- The test is for in vitro diagnostic use only.
- This test is designed for semi-quantitative detection of SARS-COV-2 neutralizing antibodies.
- It is unknown at this time if the presence of antibodies to SARS-COV-2 confers immunity to re-infection. Consider other information including clinical history and local disease prevalence, in assessing the need for a second but different serology test to confirm an immune response.
- The test results of this kit are for clinical reference only, and should not be used as the sole basis, and should be combined with other test methods, as live virus and pseudovirus neutralizing antibodies assay.