Hematology Analyzer Reagents Procan Hematology Reagent For Procan 3 Part Diff Analyzers
Intended Use
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Procan 3 part diff hematology analyzers. This product is for In Vitro Diagnostic Use only.
APPLICABLE INSTUMENT
For use with Procan PE-6800, PE-6300, PE-6000 hematology analyzers
Specification
L-D01 | Diluent PE | 20L |
L-L01 | LYSE PE | 500 mL |
L-C01 | Detergent PE | 5L |
L-C04 | 10L |
L-C05 | 20L |
L-C02 | Cleaner PE | 500mL |
L-C03 | Clair PE | 500mL |
KIT COMPOSITION
Diluent PE | NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0% |
LYSE PE | NaCl, Buffer , Surfactant |
Detergent PE | Buffer<0.3%, Sodium Sulfate<1.5% |
Cleaner PE | Buffer<0.3%, Proteolytic Enzyme<0.2% |
Clair PE | Sodium Hypochlorite |
Procedures
- Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
- Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
- Put the tubes into the LABNOVATION reagent boxes or bottles.
- Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
- Run all three levels of a dedicated commercial control. Check for the acceptable values.
- Recalibrate the unit if necessary.
Advantage
- One source for all brands of analyzer
- Reagents for both 3-parts and 5-parts
- Ready-to-use final products and bulk OEM reagents
- ISQ13485:2003 and ISO9001:2008 certified
- CE marked, FDA cleared
- Well-established brand used by thousands of lab in 95 countries
- High quality, high performance and high fidelity of correlations with original brand
Storage
- Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
- The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.
L-L01 | LYSE PE | 24 months | 30 days |
L-D01 | Diluent PE | 24 months | 60 days |
L-C01 | Detergent PE | 24 months | 60 days |
L-C04 |
L-C05 |
L-C02 | Cleaner PE | 18 months | 30 days |
L-C03 | Clair PE | 12 months | 30 days |

PRECAUTIONS
- Re-calibration is recommended when changing the origin of the reagents.
- It is not recommended using different brands of solutions together on one unit of analyzer.
- Do not ingest. Avoid contact with skin and eyes.
- Skin contact: Flush with plenty of water.
- Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
- This kit is for professionals and in vitro diagnostic use only.
FAQ
We have the limit order which is 10000, we would like to cooperate with you, don't worry about MOQ, just send us of your what items you want order.
Stock 3-7 days in general. Or please contact us by email for specific lead time base on your order quantities.
Yes, we accept both OEM and ODM for customers.
- What are your terms of delivery?
We can accept EXW, FOB, CIF, etc. You can choose one which is the most convenient for you.
- Manufacturer or Trade Company?
We're Manufacturer.