Specifications
Brand Name :
LABNOVATION
Model Number :
LX-401301
Certification :
ISO13485,ISO9001,CE
Place of Origin :
China
MOQ :
10000 Pieces
Price :
Negotiation
Payment Terms :
T/T, D/A, D/P
Supply Ability :
500000/Day
Delivery Time :
5-7 work day
Packaging Details :
Carton
Quanlity Guarantee Period :
24 months
Test Time :
Within 15 min
Package :
20 Tests/Kit
Specimen :
Nasopharyngeal Or Oropharyngeal swabs
Format :
Cassette
Method :
Immunochromatography
Description

Rapid Antigen Test Kit SARS-CoV-2 Antigen Rapid Diagnostic Test Professional Testing CE Certificated 20Tests/Kit


Intend Use

The Labnovation SARS-CoV-2 antigen rapid test kit is intended for the qualitative detection od SARS-COV-2 infection from patients. It is used for in vitro qualitative detection of the antigen of novel virus in human nasopharyngeal or Oropharyngeal swabs.
Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit
Product Details

Item Value
Model Number LX-401301
Type 20 Tests/Kit
Warranty 24 Months
Quality Certification CE
Safty Standard ISO13485
Sample Type Nasopharyngeal / Oropharyngeal Swab
Sample Volume 3 Full drops


Main Components

  • Test Cassettes
  • Sample tubes with Prefilled Sample extraction buffer
  • Swabs
  • Tube Stand
  • Instruction for use

Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit
Analytical Results

SARS-CoV-2 Antigen Rapid Test Kit
Sensitivity Specificity Total Accuracy
98.04% 100.00% 99.60%

Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit


Product Features

  • High effective, Low cost
  • One step operation, without extra equipment
  • Rapid testing, get the result within 15 minutes
  • High accuracy, sensitivity and specificity

Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit

Sample Collection

  • By nasopharyngeal swab: The sampler gently holds the head of the person to be collected with one hand, holds the swab with the other hand, sticks the swab to the nostril to enter, and slowly penetrates backwards along the bottom of the lower nasal passage, so as not to exert too much force to avoid traumatic hemorrhage. When the tip of the swab reaches the posterior wall of the nasopharynx cavity, gently rotate it for several times (in case of reflex cough, stop for a minute), and then slowly take out the swab.
  • By oropharyngeal swab: The head of the person to be collected is slightly tilted and his mouth is wide open, exposing the pharyngeal tonsils on both sides. Wipe the swab across the root of the tongue. Wipe the pharyngeal tonsils on both sides of the person to be collected back and forth with a little force for at least 3 times, and then wipe up and down the posterior pharyngeal wall for at least 3 times.

Test steps

  1. Take a sample tube (with prefilled sample extraction solution).Remove the aluminum foil sealing of the prefilled sample extraction tube and then put the tube into the tube stand.
  2. Dip the swab into the sample extraction liquid after sample collection, fully immerse the tip of the swab, rotate and squeeze the swab 10 times, then pull out the swab, and take the stranded liquid as much as possible.
  3. Close the cap of the sample tube. Add 3 full drops of the mixed solution vertically into the sample well (S) of the test cassette. Read the result 15-20 minutes after adding the sample. Result got after 20 minutes is invalid.

Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit

Result Interpretation

  • Positive: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).

  • Negative: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).

  • Invalid: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the results are not valid.


Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit

Virus Sources

Global high frequency mutation Alpha / B.1.1.7(U.K.) Beta I B.1.351(South Africa)
Gemma I P.1(Brazil) Kappa I B.1.617.1(India) Delta I B.1.617.2(India)
C.37,ect Alpha I B.1.17(U.K.) B.1.36.16.etc
A.2.5,etc A.23.1 Alpha I B.1.17(U.K.)
B.1.1.33.etc C.1.1.etc. Omicron

Limitation

1. This reagent is a qualitative detection reagent, which cannot determine the exact content of antigen.

2. The test results of this reagent are only for the reference of clinicians and should not be taken as the sole basis for clinical diagnosis and treatment. Clinical management of patients should be considered in the light of their symptoms/signs, medical history, other laboratory tests and treatment responses.

3. Restricted by antigen detection reagent method, the lowest detection limit (sensitivity analysis) is generally lower than that of nucleic acid detection, so the researchers deal with negative result to give more attention, should be combined with other test results comprehensive judgment, advice to doubt the negative result of nucleic acid detection or virus isolation culture identification method for review.

4.False negative results may be caused by unreasonable sample collection, transport and treatment, and low viral load in samples.


Certificate
Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit

Send your message to this supplier
Send Now

Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit

Ask Latest Price
Brand Name :
LABNOVATION
Model Number :
LX-401301
Certification :
ISO13485,ISO9001,CE
Place of Origin :
China
MOQ :
10000 Pieces
Price :
Negotiation
Contact Supplier
Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit
Diagnostic SARS-CoV-2 Antigen Rapid Test Kit CE Certificated 20Tests/Kit

Labnovation Technologies, Inc.

Active Member
4 Years
shenzhen
Since 2001
Business Type :
Manufacturer
Total Annual :
10000000-50000000
Employee Number :
100~600
Certification Level :
Active Member
Contact Supplier
Submit Requirement