Rapid Test Kit SARS-CoV-2 Antigen Rapid Test Kit Best Performance Antigen Rapid Diagnostic Test Self Test Use
Intend Use
This kit is an immunochromatography assay which detects SARS-CoV-2 nucleocapsid antigen in the samples with the help of the double antibody sandwich method. These rapid test kit is intended for the qualitative detection of SARS-CoV-2 viral nucleocapsid antigens from human anterior nasal of secretion from individuals suspected of COVID-19.

Product Details
Item | Value |
Model Number | LX-401302 |
Package | 1 Test/Kit |
Sample volume | 3 Full drops |
Warranty | 24 Months |
Diagnostic Accuracy
Name | Specificity | Sensitivity | Total Accuracy |
SARS-CoV-2 Antigen Rapid Test Kit | 100% | 97.45% | 99.17% |
Product Feature
- No pre-processing required, simple operation, do not need any auxiliary equipment.
- Rapid test, easy to interpret the results in 15 minutes.
- Transported and stored at room temperature.
- ISO13485, CE certificated, Safety and reliable

Main Components
- Test Cassette
- Sample tube with prefilled sample extraction buffer
- Swab
- Instruction for use

Use Step
- Take a sample tube (with prefilled sample extraction solution).Remove the aluminum foil sealing of the prefilled sample extraction tube and then put the tube into the tube stand.
- Gently, insert the entire absorbent tip of the swab (around 1.5 cm) into your nostril. Slowly, rotate the swab in a circular against the inside walls of your nostril 5 times or more. Be sure to collect any nasal drainage that maybe present on the swab. Gently remove the swab. Use the same swab to repeat steps in the other nostril and slowly, take out the swab.
- Dip the swab into the sample extraction liquid after sample collection, fully immerse the tip of the swab, rotate and squeeze the swab 10 times, then pull out the swab, and take the stranded liquid as much as possible.
- Close the cap of the sample tube. Add 3 full drops of the mixed solution vertically into the sample well (S) of the test cassette. Read the result 15-20 minutes after adding the sample. Result got after 20 minutes is invalid.

Result Interpretation
-
POSITIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
-
NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).
-
INVALID: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the results are not valid.

Virus Sources
Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
B.1.1.33.etc | C.1.1.etc. | others |
Products Feature
- For Home Use
- Results in 15 minutes
- Simple Operation
- Results are easy to read
- Safety and Reliability
- Store at 2-30 ℃
- Detect COVID-19 virus variants (UK,SA, Brazil, CA, NY, etc.)
- High sensitivity and specificity
- Sterile Swab
- In the anterior nasal swab (approx. 1.5 cm)
Certificate
- CE cetificated
- Iceland registration
- Philipines certificated
- Germant BfArm List