Specifications
Brand Name :
LABNOVATION
Model Number :
LX-401602
Certification :
ISO13485,ISO9001
Place of Origin :
China
MOQ :
10000 Pieces
Price :
Negotiation
Payment Terms :
T/T, D/A, D/P
Supply Ability :
1000000/Day
Delivery Time :
On-time delivery
Packaging Details :
Carton
Quanlity Guarantee Period :
24 months
Test Time :
Within 15 min
Storage Condition :
2℃-30℃
Specimen :
Saliva
Sunshine :
Avoided
Freeze :
Avoided
Description

SARS-CoV-2 Antigen Saliva Rapid Test Kit Saliva Sample Virus Antigen Rapid Diagnostic Single Packing Self Testing Use


Intend Use

The SARS-CoV-2 Antigen Saliva Rapid Test Kit is used to qualitatively detect SARS-CoV-2 antigen in saliva samples of suspected patients with new coronavirus. The positive result of the antigen test can be used for early classification and rapid management of suspected populations.

15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2

Product Details

Item Value
Name SARS-CoV-2 Antigen Saliva Rapid Test Kit (Self Test)
Warranty 24 Months
Safty Standard ISO13485
Sample Type Saliva specimen
Sample volume 3 Full drops
Test Speed Within 15 minutes

Product Feature

  • Quick Test: get the result in 15 minutes
  • High Accuracy, sensitivity and specificity
  • Simple to use
  • Accurate and reliable
  • Store at room temperature

15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2

Diagnostic Accuracy

SARS-CoV-2 Antigen Saliva Rapid Test Kit
Sensitivity Specificity Total ACCURACY
96.19% 100.00% 99.21%



Main Components

  • Test Cassette
  • Saliva Collector
  • Disposable Pipettes
  • Sample Extraction Buffer (single dose)
  • Instruction Insert

Use Step

  • Take sample tube with prefilled sample extraction buffer and remove the sealed film of the sample tube. Then put the tube into tube stand (in the outer box).
  • Open the tear hole of the aluminum foil bag, take out the disposable pipette and test cassette, lay them flat.
  • Put the saliva collection bag to lips and let
    the saliva flow into the bag.
    Place the tip of tongue against the upper or lower tooth root to enrich saliva, and then swallow saliva to the throat without ingesting saliva to esophagus, followed by returning saliva to the mouth. Repeat the process for 5 times.

15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2

  • Draw 2/3 dropper range(300ul)of saliva from saliva collection bag with the help of pipette and transfer the entire contents into the extraction buffer of the sample tube. And blow the liquid for 10 times, squeeze bottom of the sample tube to ensure the saliva is thoroughly mixed.
  • Close the cap of the sample tube.
    Shake the specimen collection tube at least three times vigorously to mix the saliva sample with extraction buffer. Attention: Please avoid bubbles!
  • Add 3 full drops of the treated sample extraction buffer (about 70μL-100μL) vertically into the sample well of the test cassette.
    Read the result at 15 minutes. Do not interpret the result after 20 minutes.

15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T).

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure.



15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2
Virus Sources

Global high frequency mutation Alpha / B.1.1.7(U.K.) Beta I B.1.351(South Africa)
Gemma I P.1(Brazil) Kappa I B.1.617.1(India) Delta I B.1.617.2(India)
C.37,ect Alpha I B.1.17(U.K.) B.1.36.16.etc
A.2.5,etc A.23.1 Alpha I B.1.17(U.K.)
B.1.1.33.etc C.1.1.etc. Omicron

Other Information

  • Not following the exact instructions can affect the outcome of the test. The final diagnosis must be confirmed by a physician.
  • Do not use the test if the packaging is damaged. Do not use broken test components.
  • All test components are only intended to be used for this test. Do not reuse the test or test components.
  • The test should be carried out immediately or within one hour after opening the foil pouch (18-30°C, humidity <60%).
  • Samples be processed as soon as possible after sample collection. If the test cannot be performed immediately, the sample should be stored in a sealed state, stored at 2~8°C for 8 hours. Long-term storage is not recommended.

Send your message to this supplier
Send Now

15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2

Ask Latest Price
Brand Name :
LABNOVATION
Model Number :
LX-401602
Certification :
ISO13485,ISO9001
Place of Origin :
China
MOQ :
10000 Pieces
Price :
Negotiation
Contact Supplier
15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2
15 Min Antigen Saliva Rapid Test Kit Single Packing Self Testing For SARS CoV 2

Labnovation Technologies, Inc.

Active Member
4 Years
shenzhen
Since 2001
Business Type :
Manufacturer
Total Annual :
10000000-50000000
Employee Number :
100~600
Certification Level :
Active Member
Contact Supplier
Submit Requirement