Rapid Test Kit Antigen Test Kit SARS-CoV-2 Antigen Rapid Test
Intend Use
- Qualitative detection of SARS-CoV-2 viral nucleocapsid antigens from human anterior nasal of secretion from individuals suspected of COVID-19 Positive result of the antigen test can be used for early isolation of patients with suspected infection,
- It cannot be used as diagnosis basis of SARS-CoV-2 infection
- Negative results do not rule out SARS-CoV-2 infection and should not be used as the sole basis for treatment
- Nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative
Product Details
Item | Value |
Brand | Labnovation |
Model Number | LX-401305 |
Package | 5 Tests/Kit |
Warranty | 24 Months |
Quality Certification | CE, MSDS |
Safty Standard | ISO13485 |
Sample Type | Nasal Swab |
Sample volume | 3 Full drops |
Test Speed | Within 15 minutes |

Product Feature
- Fast: Result in 15 minutes and easy to read
- Accurate: High Accuracy, Specificity and Sensitivity
- Reliable: Individual package, safety and clean
- Simple: Easy to operate, one step operation process

Main Components
- 5 Test Cassettes
- 5 Sample tubes
- 5 Extraction Buffer
- 5 Swabs
- 1 Tube stand
- 1 Instruction for use

Use Step
- Open the sealed pouch and remove the test casstette. Lay it face up on a clean, dry and flat surface.
- Unpack the sample extraction, add all of the sample extraction into the sample tube and then put the tube into tube stand.
- Gently, insert the entire absorbent tip of the swab (around 1.5 cm) into your nostril. Rotate walls of your nostril 5 times or more. Use the same swab to repeat steps in the other nostril.

- Insert the swab into the ssample tube with extraction buffer. Mix well. Mix well and squeeze the swab 10-15 times by compressing the walls of the tube against the swab. Roll the swab head against the inner wall of the tubes as you remove it.
- Close the cape of the sample tube. Add 3 full drops of the mixed solution vertically into the sample well(S) of the test cassette.
- Read the result 15-20minutes after adding the sample. Result got after 20 minutes is invalid.

Result Interpretation
-
POSITIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
-
NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).
-
INVALID: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the results are not valid.

Virus Sources
Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
B.1.1.33.etc | C.1.1.etc. | |
Certificate