Handheld Ophthalmic Equipment Electronic Keratometer Wireless Print
Model : MCE-SW-100
Introduction:
Dear User:
Welcome to use SW-100 Electronic Keratometer.
We introduce this instrument to you by two parts: interface and operation. This User’s Guide is designed as a training and reference manual. We recommend you read carefully and follow the steps in this guide to ensure that the machine would have optimal performance.
Product Performance:
Electronic Keratometer is made of three parts, including light source, Measurement of optical system and display system. To focus, the operator need make the unit up and down, , back and forth. When the focusing condition is met, When all the four image points are in the center of the screen, instrument will calculate automatically the curvature radius and diopter and display the result on the screen.
Technical Data
- Measuring range:6.5mm~9.5mm curvature radius
- Center measuring area of Corneal Radius: Φ3mm~Φ4mm;
- Digital Display Resolution of curvature radius: 0.01mm;
- Precision of curvature radius of cornea: ±0.05mm;
- Axial resolution of the main meridian: 1°;
- Radial deviation of the measurement of the main meridian
- a)curvature radius deviation of the main meridian≤0.3mm, measurement of main meridian axial deviation: ±4°;
b)curvature radius deviation of the main meridian>0.3mm,measurement of main meridian axial deviation: ±2°;
- Output: Wireless infrared thermal printer;
- Voltage: DC4.5V(three AA battery);
- Rated input power: 500mW+15%;
- Weight: <0.5kg;
- Dimension: 240mm×90mm×60mm.
Environmental requirement
Transport and save:
Ambient temperature: -40℃~+55℃
Relative moisture: ≤95%
Atmospheric pressure: 500hPa~1060hPa
Working;
Ambient temperature: +5℃~+40℃
Relative moisture: ≤80%
Atmospheric pressure: 700hPa~1060hPa
Installation
1. refer to the packing list, and check missing
2. Put the battery in the battery compartment
3. Press the power button and start the unit
Product maintenance
1.Routine maintenance
- This instrument should be store in a place with good ventilation, and without direct sun irradiation.
- Don’t use organic solution to clean the instrument, like thinner, or it will cause instrument corrosion. Avoid any water or other liquid filtering into the machine. Switch off before cleaning.
- This ketatometer is a delicate instrument, don’t press, shock or drop it with strength.
- Check the batteries periodically to see if they are corroded. If the machine hasn’t been put into use for a long time, the batteries should be taken out.
- Don’t try to disassemble the machine yourself when there comes a problems. Please contact the company or the sales person.
2.Cleaning lens
The screen, lens and illuminants of this instrument should be wiped with special tissue to avoid any laceration.
3.Calibration
- Keratometer should calibrate with standard eyeball which used for cornea measuring ;
- After keratometer repairing, it calibrate with standard eyeball which used for cornea measuring
Package and transport
Packed Keratometer is not allowed transport with flammable, explosive, corrosive items at the same time, It should keep away from shock, severe vibration and moisture in the transportation.
Curvature should be stored at ambient temperature -20 ℃ ~ 55 ℃, relative humidity of 10% to 100%, non-corrosive gases, strong mechanical vibration, shock and magnetic field environment. Avoid direct sunlight, with good indoor ventilation.
Trouble shooting
If the instrument is not working properly, please refer to the table below. If the problem persists, please contact the company or dealer
Fault | Reason | suggestion |
No response on screen | - Not power on;
- Batter is dead;
- Forget put in battery;
| - Power on;
- change a new battery;
- Put in batter;
|
In the easurement process, the screen flashing or system halted | - Batter is dead;
- Software system is defective;
| - change a new battery
- Restart, if still not working please contact with us.
|
Can’t capture the six light spot, or the light spot is irregular | - Light path with failure;
- Light source and lens is uncleanly;
- Eyelids and eyelashes cover the eyes and or focus area;
- Patient’s eyes with tear;
- Patient lost tear film;
- Cause local scar;
| - Please contact with us;
- Clean the lens or the light source
- Adjust the measurement position or increase the openness of the eyelids;
- Open and close the eyes several times, eliminating tears;
- Open and close the eyes several times improve the tear film, and then operate;
- Adjust the placement of light spot
|
Continuously measure several times, the standard deviation is more than 0.02 | - The posture of operator or the patients is not correct, in the measuring process, shaking is more powerful
- Tear film break;
| - Re-adjust the position, ensure that the Keratometer plane and axial corneal curvature is perpendicular.
- Validity of measurement is not reliable.
|
Can’t get the measured data | - Caused by ambient light, stray light on the screen, or the light spot is not round, etc
- Keratometer plane and the axial curvature is not vertical, resulting in light spot is not round and streak
- Focusing distance too close to cornea;
- When focusing it is too fast to approach the cornea;
| - Take the measurement in the dark room.
- Adjust the Keratometer, make it Perpendicular to the axial
- At a distance of 40mm away from the center of the cornea, start approaching the cornea to focus
- In the approximation process of the cornea, the speed can’t be too fast , or else it’ll missed the focus position.
- Can’t be measured;
|
Can’t print data | - There is no data currently
| - Check if there is print paper, and if not, put in printing paper
- Check if the Printer paper is jamed ,if it is, draw out the printer paper.
- Check if the current interface has a valid data.
|
Warranty:
All the accessories should be well kept. If anything is missing, the instrument could not be warranted.
This instrument had been strictly inspected and tested before putting into sales. We will offer free service or change defective parts only in the warranty period. But it will not prolong the warranty period, and the replaced defective part should be sent back to Suowei company. We will not take the responsibility if it is broken because of the wrong operation of user.
All the pictures in this guide is for reference only, please see practicality as standard.
Users to purchase their own printer with infrared interface


