Gynecological Operating Room Equipment Mobile Electric Suction Machine Surgical
Model: MCS-DFX-23C.IV
F-eatures Of Portable Phlegm Suction Unit:
DFX-23C·III,DFX-23C·V electrical suction units are new style mobile suction devices.They are devices for medical use designed for operations of gynecology in hospitals for taking out pus, blood, sputum and other thick liquid in human body.
F-eatures
◆23C·V All-plastic ABS enclosure that is formed in one piece is adopted.
◆The device is equipped with a imported membrane pump available with long service life.
◆ This device has low noise and is maintenance-free.
◆ This device is equipped with an overflow protection unit to prevent liquid from getting into pump body.
◆ It’s equipped with the hand-operated switch and footstep-operated switch.
Model: MCS-DFX-23C.IV
TECHNICAL SPECIFICATION:
Power voltage:AC220V±10% 50Hz
Negative pressure:≥0.09MPa(680mmHg)
Suction rate:≥25L/min
Range of negative pressure:0.013MPa~0.09Mpa(680mmHg)
Suction bottle:2500ml x 2
Noise:≤55dB
Input power:150VA
Pump structure:Diaphragm type
Working type:intermittent loading,continuous operation
TECHNICAL SPECIFICATION: |
Power voltage:AC220V±10% 50Hz Negative pressure:≥0.09MPa(680mmHg) Suction rate:≥25L/min Range of negative pressure:0.013MPa~0.09Mpa(680mmHg) Suction bottle:2500ml x 2 Noise:≤55dB Input power:150VA Pump structure:Diaphragm type Working type:intermittent loading,continuous operation |
NOTE:
1.vehicle frame design,easy movement
2.imported diaphragm pump
3.long service life time
4.plastic bottle for cleaning & disinfection
5.oil-free pump is maintenance-free
6.low noise
7.with an overflow protection
DIMENSION (CM):55×50×96
PACKAGE: Wooden
G.W. : 36KG
Model: MCS-DFX-23C.IV
TECHNICAL SPECIFICATION:
Power voltage:AC220V±10% 50Hz
Negative pressure:≥0.09MPa(680mmHg)
Suction rate:≥25L/min
Range of negative pressure:0.013MPa~0.09Mpa(680mmHg)
Suction bottle:1000ml x 2
Noise:≤55dB
Input power:150VA
Pump structure:Diaphragm type
Working type:intermittent loading,continuous operation
TECHNICAL SPECIFICATION: |
Power voltage:AC220V±10% 50Hz Negative pressure:≥0.09MPa(680mmHg) Suction rate:≥25L/min Range of negative pressure:0.013MPa~0.09Mpa(680mmHg) Suction bottle:1000ml x 2 Noise:≤55dB Input power:150VA Pump structure:Diaphragm type Working type:intermittent loading,continuous operation |
NOTE:
1.imported diaphragm pump
2.low noise
3.with an overflow protection
4.instrument tray at the top
5.oil-free pump is maintenance-free
DIMENSION (CM):47×44×81.5
PACKAGE: Carton
G.W. : 28KG