Specifications
Brand Name :
MeCan
Model Number :
MC-500
Certification :
ISO
Place of Origin :
GuangZhou
MOQ :
1 set
Price :
Inquiry
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
500 sets per week
Delivery Time :
3-15 working dates
Packaging Details :
Carton/Wooden packing
Product :
ICU ventilator
Respiratory Rate :
6~60 times/ min
Oxygen concentration output :
<50%
modes of ventilation :
A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL
IMV frequency :
1~12 bpm
Tidal Volume :
0-1500ml
Maximum Safety Pressure :
≤ 6.0kPa
Gas requirement :
Medical oxygen with a pressure ranging from 280~600kpa
Description

CE Approved Electrically Controlled Pneumatic Ventilator Portable ICU Ventilator

Model : MC-500

Prospective service and support

The MC-500 ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. It is mainly intended for providing ventilation support to a critically ill patient during the life threatening phase and ensuring the going-through of the dangerous period by the patient and smooth treatment of primary diseases for recovery. Also it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.

Display: LED Display Following Parameters

Operating mode and respiratory rate;

——Ventilator control frequency set by medical staff;

——Tidal volume of each breath in the patient;

——Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;

——Expiratory phase and inspiratory phase and actual respiratory rate;

——Minute volume;

——Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure;

Portable Ventilator Construction :

--Environmental Protection Material construction, hardly to be broken.

-- Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions

TECHNIQUES SPECIFICATIONS
Physical specifications
Display LED Display
Mode: pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen with a pressure ranging from 280~600kpa
safety valve <12.5 kPa
Respiratory Rate 6~60 times/ min
Oxygen concentration output <50%
minute volume ≥18L
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL
PEEP: 0.1 ~ 1.0 kPa
Ptr: -4 ~ 10 hPa
IMV frequency: 1~12 bpm
I/E Ratio: 1:1.5; 1:2.0; 1:2.5; 1:3.0
Tidal Volume 0-1500ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range: 0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.9 kPa ~ 5.4 kPa; Upper: 0.5 kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;
Attention: the AC power supply used for the anesthesia machine must be well grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min; Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.

Electrically Controlled Pneumatic Ventilator , Portable Ventilator For Ambulance

Send your message to this supplier
Send Now

Electrically Controlled Pneumatic Ventilator , Portable Ventilator For Ambulance

Ask Latest Price
Brand Name :
MeCan
Model Number :
MC-500
Certification :
ISO
Place of Origin :
GuangZhou
MOQ :
1 set
Price :
Inquiry
Contact Supplier
Electrically Controlled Pneumatic Ventilator , Portable Ventilator For Ambulance
Electrically Controlled Pneumatic Ventilator , Portable Ventilator For Ambulance

Guangzhou MeCan Medical Limited

Active Member
9 Years
guangdong, guangzhou
Since 2006
Business Type :
Manufacturer, Distributor/Wholesaler, Trading Company
Total Annual :
20000000-30000000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier