Specifications
Brand Name :
AI
Model Number :
CPT-3
Certification :
ISO
Place of Origin :
China
MOQ :
1 Set Current Transformer Test Instrument
Price :
Negotiable
Payment Terms :
T/T, Western Union, L/C
Supply Ability :
100000 sets per month
Delivery Time :
15 days
Packaging Details :
Current Transformer Test Instrument packed in Plywood case
Power supply :
AC220V±10%, 50/60Hz±10%
Display :
LCD
Keyword :
CT Analyzer Current Transformer Tester
Standard :
EC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Measuring range :
0~200V
Current Measurement :
0~10A
Turns ratio measurement Range :
1-35000
Coil resistance measurement :
0~80Ω
Description

Current Transformer CT Analyzer CT Testing Equipment

Tester for current transformer:

1.Excitation curve and parameters test
2.Turns ratio test
3. Ratio and phase error test
4. Polarity mark check
5. Coil resistance measurement
6. Secondary loop burden measurement
7. Error line curve test for protection CT
8. Transient CT parameters test
9. CT nameplate guess
10.Saturation hysteresis loop curve measurement

Applications of CT Current Transformer Tester:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration

Specifications:

Item Name CT Current Transformer Tester
Test standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply AC220V±10%, 50/60Hz±10%
Voltage output 0.1~125V (AC)
Current output 0.001~5A(RMS)
Power output 300VA
Max. knee voltage measurement 45KV
Current measurement Range 0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS

Voltage measurement Range 0~200V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
Turns ratio measurement Range 1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement error ±2min
resolution 0.01min
Coil resistance measurement Range 0~80Ω (automatically change range in 2ohm/20ohm/80ohm)
Error < 0.2%RDG+0.02%FS
Maximum resolution : 0.1mΩ
Temperature measurement -50~100 Celsius degree; error<3 Celsius degree
CT Secondary burden Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
Memory capacity >1000 groups test results
Working condition temperature -10℃~50℃; moist ≤90%

IEC 60044 Electrical CT Analyzer Current Transformer Test Instrument

Send your message to this supplier
Send Now

IEC 60044 Electrical CT Analyzer Current Transformer Test Instrument

Ask Latest Price
Brand Name :
AI
Model Number :
CPT-3
Certification :
ISO
Place of Origin :
China
MOQ :
1 Set Current Transformer Test Instrument
Price :
Negotiable
Contact Supplier
IEC 60044 Electrical CT Analyzer Current Transformer Test Instrument
IEC 60044 Electrical CT Analyzer Current Transformer Test Instrument
IEC 60044 Electrical CT Analyzer Current Transformer Test Instrument
IEC 60044 Electrical CT Analyzer Current Transformer Test Instrument

Advanced Instruments Co.,Limited

Verified Supplier
6 Years
hunan, changsha
Since 2018
Business Type :
Manufacturer, Trading Company
Total Annual :
1,000,000-5,000,000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement