Specifications
Brand Name :
AI
Model Number :
TDT
Certification :
ISO
Place of Origin :
China
MOQ :
1 Set
Price :
Negotiable
Payment Terms :
T/T, Western Union, L/C
Supply Ability :
100000 sets per month
Delivery Time :
15 days
Packaging Details :
Plywood case
Power supply :
220V±10%
Display :
LCD
Keyword :
Tan Delta Test, Loss Angle Test, Dissipation Factor Test
Weight :
28KG
Size :
350*270*270mm
High output :
0.5KV~10KV(12KV can be customized)
Warranty :
1 Year
Maximum current :
200mA
Description

Transformer Tan Delta Test Equipment

I.Introduction:

TDT Tan Delta Test Equipment is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

This Loss Angle Test Equipment can also supply high voltage source for testing.

Frequency can be changed to 50Hz, 47.5Hz52.5Hz,45Hz55Hz, 60Hz, 57.5Hz62.5Hz, 55Hz65Hz; thus, this power factor tester can avoid interference of power frequency;

This dissipation factor test equipment can also be used as power supply;


II.Specifications:

No. Item Name Transformer Tan Delta Test Loss Angle Test Dissipation Factor Test Equipment
1 Use conditions -15℃~40℃ RH<80%
2 Anti-interference Frequency conversion
3 Power AC 220V±10% Allowable generator
4 High output 0.5KV~10KV Every 0.1kV
Precision 2%
Maximum current 200mA
Capacity 2000VA
5 Self-excited power AC 0V~50V/15A

45HZ/55HZ 47.5HZ/52.5HZ

55HZ/65HZ 57.5HZ/62.5HZ

Automatic double frequency

6 Resolving power tgδ: 0.001% Cx: 0.001pF
7 Precision tgδ:(Reading*1.0%+0.040%)
Cx :(Reading*1.0%+1.00PF)
8 Measuring range tgδ Unlimited
Cx 15pF < Cx < 300nF
10KV Cx < 60 nF
5KV Cx < 150 nF
1KV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT range 10~10000
accuracy 0.1%
Resolving power 0.01
10 Dimension 350*270*270mm
11 Memory size The 200 group supports U disk data storage
12 Weight

28 Kg

Spares of Transformer Tan Delta Test Loss Angle Test Dissipation Factor Test Equipment

Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
NO. Name Quantity Unit
1 Main Unit 1 Set
2 Accessory case 1 PC
3 Red HV test cable 1 Root
4 Black LV test cable 1 Root
5 AC220V power cable 1 Root
6

CVT self-excited power cable (attached)

1 Root
7

Ground wire

1 Root
8 Fuse, printer paper Spare
Send your message to this supplier
Send Now

Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test

Ask Latest Price
Brand Name :
AI
Model Number :
TDT
Certification :
ISO
Place of Origin :
China
MOQ :
1 Set
Price :
Negotiable
Contact Supplier
Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test

Advanced Instruments Co.,Limited

Verified Supplier
6 Years
hunan, changsha
Since 2018
Business Type :
Manufacturer, Trading Company
Total Annual :
1,000,000-5,000,000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier