Minimum Oxygen Concentration Tester packed in Plywood case
Test standard :
ASTM D 2863, ISO 4589-2
Measuring range :
0~100%
Accuracy :
± 0.1%
Response time :
1s
Diplay :
Touch screen
Dimension :
400*537*584mm
Weight :
50KG
Power supply :
AC 220V, 50/60Hz, 5A
Description
Introduction: This Oxygen Concentration Tester measures minimum oxygen concentration as necessary when specimen combustion. The oxygensensor is adapted Paramagnetic Type which has a precise, long life, less error rate and high reliability. The Oxygen Concentration Tester meets the requirements of standards like ASTM D2863, ISO 4589-2, NES714 and so on.
Features: 1. Oxygen sensor, accuracy<0.1%; 2. Touch screen setting of oxygen percentage concentration, automatic adjustment; 3. Digitally display nitrogen flow rate and mixed gas flow rate; 3. One click setting, automatic ratio display of oxygen percentage concentration, without the need for manual adjustment and calculation; 4. High temperature and heat-resistant quartz glass cylinder, capable of withstanding high temperatures during testing; 5. Gas ignition device, with adjustable flame length and the ability to cut off the gas source; 6. Provide sample holders for supportable samples and unsupportable samples; 7. The quartz cylinder can automatically rise or fall, making it easy to replace samples; 8. Gas pipeline optimization design, providing faster response time; 9. The air circuit is a mass flow controller; 10.The controller adopts an imported programmable controller. 11.Adopt imported Paramagnetic oxygen analyzer and Mass flow meter.
Technical Specifications 1. Overall dimension: 400*537*584mm (W * D * H) 2. Oxygen concentration output: 0% -100%, set directly on the touch screen 3. Oxygen concentration measurement: 0-100% 4. Measurement resolution: 0.1 5. Measurement range: 0-100% 6. Working pressure: 0.05-0.3 Mpa. 7. Combustion tube height: 500mm 8. Inner diameter of combustion cylinder: 76mm 9. Restriction hole at the top of the combustion cylinder: Φ 40mm 10. Combustion tube flow rate :(40 ± 2) mm/s 11. Response time: 1 second 12. Measurement accuracy: ± 0.2% (10% -60%) accuracy within the range 13. Test time: 0.1s~999.9s 14. Residual flame recording time: 0.01s~999.9s 15. Ignitioin method: manual ignition 16. Box material: aluminum and stainless steel 17. Sample holder: multiple options available 18. Glass cylinder: high-temperature resistant quartz glass cylinder with a diameter of 75mm and a mouth of 40mm; 19. Igniter: There are two methods: handheld igniter and machine controlled igniter (propane); 20. Oxygen control: mass flow meter controller Nitrogen control: mass flow meter controller