Door Roller Blind Fire Tester
Uses
It is suitable for the fire resistance test of the building with the door, the door and the roller blind. The fire resistance limit is determined by experiment.
Technical parameters
1. Working voltage: AC 380v ± 10% 50hz; electricity consumption: 3kw
2. Furnace pressure measurement range: 0-100pa measurement accuracy: ≤ ± 3pa
3. Air flow: 0-50m3 / min measurement accuracy: ≤ ± 0.5 m3 / min
4. Combustion gas source: propane, liquefied gas
5. Gas flow: 0-100l / min measurement accuracy: 2.5
6. Gas tank capacity: 50kg × 6
7. The test piece backfire surface radiant heat measurement range: 0 ~ 10w / cm2;
8. The pressure measurement range of the furnace: indoor pressure ± 150mpa;
9. Test temperature: program temperature 15min room temperature ~ 718 ° C, 30min room temperature ~ 821 ° C, 60min room temperature ~ 925 ° C, 90min room temperature ~ 986 ° C, 120min room temperature ~ 1029 ° C