Cable Electronic Testing Equipment IEC60695 Needle Flame Test Chamber
Introductions
Needle Flame Test Chamber is used to test the resistance of fire caused by an interior fault such as leakage current in cable & wire and the like. It meets the requirements of Chinese and IEC60695-2-2 and IEC61347-1 standards.
Application
Electrician & electron product
Components and accessories of household appliances
Features
a.All stainless steel and brass constructions.
b.Burner can be ignited automatically.
c.Temperature and test time display by digital meters.
d.A big window in the door makes your viewing more convenient.
Technical parameter
Needle burner | inner hole diameter Φ 0.5mm ± 0.1mm, Diameter,9mm≤Φ, length ≥ 35mm, stainless steel |
Burner angle | 0,°20°, 45° (adjust flame height) |
Thermocouple | Ø0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand temperature-40°C~ 1100°C |
Burning time | 0-999.9 s ± 0.1 s adjustable (usually selected for 30s) |
Hold Burning time | 0-999.9 s ± 0.1 s, automatic recording, manual time-out |
Flame Height | 12mm ± 1mm (with height measurement instruments) |
Flame Gas | butane gas/Butane gas, min. 95% purity (can use bottled lighter gases) |
Temperature Test Range | 0~1000°C |
Flame Temperature Requirements | from 100 °C ± 2 °C liters to 700 °C ± 3 °C time in 23.5 seconds ± 1 seconds |
Standard Copper Block | 4mm±0.01mm, weight.0.58g±0.01g before drilling. Cu-ETP |
Test process | automatic control, independent convulsions |
Chamber | ≥0.5m3 |
Control | Using single chip microcomputer + touch screen control |
Consult standard | GB/T5169.10-2006 , IEC60695-11-5:2000,UL746A |
Power Supply | 800VA ,220V, 48-60Hz |
Display panel language | English(customize available) |